We provide you with diverse project testing solutions and can customize software according to your needs

News&Events

Information Details


Automatic Transformer Test System User Correction

Open‑circuit, short‑circuit, and load correction functions are primarily used to eliminate distributed capacitance, parasitic impedance, and other measurement errors. The automatic transformer test system offers two correction methods.

Release date:

2014-02-18

On the [Transformer Test Settings] page, press the softkey labeled “User Correction” to enter the [User Correction] page.

On the [User Correction] page, the following measurement control parameters can be configured:

♦ Open-circuit correction (open circuit)

♦ Load Correction (Short Circuit)

♦ Cable Length Selection (Cable)

♦ Single‑channel/Multi‑channel Correction Mode Selection (Mode)

♦ Load Correction Test Function (Function)

♦ Frequency points for open-circuit, short-circuit, and load correction (Frequency 1, Frequency 2, and Frequency 3)

♦ Load‑corrected reference values for three frequency points (Reference A, Reference B)

♦File Management (Files)

♦Auxiliary Tools (Tools)

Open‑circuit, short‑circuit, and load correction functions are primarily used to eliminate distributed capacitance, parasitic impedance, and other measurement errors. The automatic transformer test system offers two correction methods: one employs the insertion method to perform open‑circuit and short‑circuit corrections across all frequency points; the other applies open‑circuit, short‑circuit, and load corrections only at the currently selected frequency point.

Please note: The following information is displayed on this page only and cannot be configured.

♦ In multi-channel correction mode, the current channel number (channel)

♦ Actual test results of load correction (Measurement A, Measurement B)

The current multi-channel correction channels can be configured via a multiplexed scan interface or a TEEE488 interface.

The actual test results of load correction can be evaluated within the frequency settings for Frequency 1, Frequency 2, and Frequency 3.