ZX9604 Series Independent Multi-Channel Hipot Tester

The ZX9604 series independent multi-channel hipot testers are a new generation of cost-effective instruments launched by Changzhou Zhixin. In this series, each high-voltage unit operates and outputs independently in parallel without interfering with one another. A single main unit supports the output and measurement of up to four high-voltage units. This series resolves the issue of arcing between pins caused by out-of-phase voltages when multiple traditional testers are used simultaneously to test multiple products. It allows four identical products to be tested at a single workstation, saving labor, significantly improving testing efficiency, and reducing space requirements.
  • File size: 4.2MB

  • File size: 386.8KB

  • File size: 1.7MB


Product Model

Model

Overview

Product Brochure

ZX96044 independent units for AC, DC, and IR testing; AC Voltage: 0.10–5.00 kV; AC Current: 0 mA–10.00 mA; DC Voltage: 0.10–6.00 kV; DC Current: 0 μA–5.00 mA; IR Voltage: 0.10–1.00 kV; IR Resistance: 1 MΩ–10 GΩ.

Click to View

ZX9604A4 independent units for AC testing; AC Voltage: 0.10–5.00 kV; AC Current: 0 mA–10.00 mA.Click to View
ZX9604CK4 independent units for AC, DC, and IR testing; AC Voltage: 0.10–5.00 kV; AC Current: 0 mA–10.00 mA; DC Voltage: 0.10–6.00 kV; DC Current: 0 μA–5.00 mA; IR Voltage: 0.10–1.00 kV; IR Resistance: 1 MΩ–10 GΩ; with Contact Check (CK) function.Click to View

Functions & Advantages

● 7-inch LCD color screen display   

● Chinese/English operation interface   

● One mainframe supports up to four hipot units   

● Four hipot units with independent output and measurement

● AC/DC/IR all-in-one safety test    
● Each unit can be expanded via scanner box

● Scanner box supports contact check function    
● Fast discharge and arc detection functions

● Key lock function   

● Automatically saves current settings and recalls them on next startup   

● Independent judgment result display for each unit, with overall result display   

● Independent sorting output for each unit's judgment result, convenient for connection to automated equipment


Core Measurement Technologies

◆  Synchronous Testing

When performing withstanding voltage testing on multiple DUTs, a common issue is output asynchronization. During production line planning or automation design, space is often maximized, resulting in very small distances between two DUTs. Taking 5 kV AC output as an example, when the hipot tester outputs are out of sync, a peak voltage difference of up to 14 kV can occur between adjacent DUTs, causing discharge that damages fixtures and leads to test misjudgment. The ZX9604 series synchronizes output signals, preventing high-voltage discharge between adjacent test units, thereby extending production line equipment life and reducing test misjudgments.

◆  Arc Detection (ARC)

The ZX9604 series features arc detection capability. This function is used to detect current transients caused by localized instantaneous arcing in the high-voltage test loop. Such transients are superimposed on the normal test current and are of short duration, making them difficult for conventional current detection circuits to respond to effectively. The arc detection circuit filters out the normal test current and processes only high-speed current pulse variations. Due to low-pass filter characteristics and the inherent randomness of arc magnitude, this function can only provide an approximate assessment of localized arcing severity.

◆  Open/Short Circuit Detection (OS)

The OS function is used to detect open circuits (poor contact) or short circuits (DUT shorted) during testing. If an open circuit occurs during testing, defective products may be falsely judged as good. If a short circuit occurs, early detection and screening can reduce damage to fixture equipment and save test costs.

General hipot test products exhibit capacitive characteristics (Cx), with normal capacitance values ranging from tens of pF to several μF. When an open circuit occurs at the connection, the open interface forms a small capacitance (Cc), and the overall capacitance value becomes far lower than that of a normal product. When the DUT is shorted or nearly shorted, the overall capacitance value becomes far higher than normal. Therefore, the open/short condition can be determined by monitoring capacitance value changes against threshold levels.

Parameters & Dimensions

ModelZX9604ZX9604AZX9604CK
Number of units4 independent units4 independent units4 independent units
Withstanding Voltage Test
Output VoltageAC

0.10 kV to 5.00 kV (customizable up to 6 kV)

Accuracy: ±(2% of reading + 5 digits)

DC

0.10 kV to 6.00 kV

Accuracy: ±(2% of reading + 5 digits)

-----

0.10 kV - 6.00 kV

Accuracy: ±(2% of reading + 5 digits)

Current Test RangeAC

0 mA to 10.00 mA

Accuracy: ±(2% of reading + 5 digits)

DC

0 μA - 5.00 mA

Accuracy: ±(2% of reading + 5 digits)

-----

0 μA - 5.00 mA

Accuracy: ±(2% of reading + 5 digits)

Discharge FunctionAutomatic discharge after test (DCW) Without discharge function
Insulation Resistance Test
Output Voltage

0.10 kV to 1.00 kV (customizable up to 6 kV)

Accuracy: ±(2% of reading + 5 digits)

------

0.10 kV to 1.00 kV (customizable up to 6 kV)

Accuracy: ±(2% of reading + 5 digits)

Resistance Measurement Range1 MΩ to 50 GΩ------1 MΩ to 50 GΩ
Resistance Measurement Accuracy<500 V1 MΩ to 999 MΩ ±10%------1 MΩ to 999 MΩ ±10%
≥500 V

1 MΩ to 999.9 MΩ ±10%

1 GΩ to 10 GΩ ±20%

------

1 MΩ to 999.9 MΩ ±10%

1 GΩ to 10 GΩ ±20%

Arc Detection
Measurement Range (Current)1 mA to 20 mA
General Parameters
Voltage Rise Time0.1 s to 999.9 s
Test Time Setting (AC/DC)0.2 s to 999.9 s
Voltage Fall Time0.1 s to 999.9 s
Waiting Time0.2 s to 999.9 s
Time Accuracy±(1%+0.1 s)
MemoryStore 100 test files, up to 20 test steps per file
Interface
StandardHANDLER, RS-232C, USB HOST

 

Unit: millimeters (mm)

Accessories & Options

ZX95Y02R Test Cable

ZX95Y02R Test Cable

ZX96Y01B Test Cable

ZX96Y01B Test Cable

ZX95Y06 Test Cable

ZX95Y06 Test Cable

ZX9610Y01R+B Test Cable

ZX9610Y01R+B Test Cable

ZX95Y05R Test Cable

ZX95Y05R Test Cable

Software & Resources

Solutions

undefined

undefined

Customer Q&A

Q: Why does sparking occur during measurement?

A: Adding ferrite cores to the test leads can help reduce the occurrence of sparking.

Q: Why is the current consistently zero during instrument measurements?

A: Make sure there is no short circuit between the two layers of the low-side shielded cable.

Q: Why is there a current reading (or an abnormally low resistance reading) during an open-circuit test after the fixture is connected?

A: Ensure that the test fixture itself has good insulation. If the reading returns to normal when all test leads are removed, the issue is most likely due to insufficient insulation of the test fixture. For minor current offsets, the baseline can be cleared using the zeroing function.

Total 3 < 1 >

Enter information to retrieve data.

By systematically retrieving and analyzing relevant input information, comprehensive and specialized data are obtained to support or meet specific needs or objectives.

Confirm