ZX2735 Series Magnetic Core Characteristic Tester

The ZX2735 series magnetic core characteristic tester (volt-ampere characteristic tester) is a smart dedicated instrument designed specifically for production-line sorting of ferrite and other magnetic cores. It can also function as a low-voltage AC constant current source or an AC millivoltmeter, with a minimum resolution of 1 μV. This instrument simulates and measures the induced voltage generated by a single-turn winding on the core under operating frequency and current, enabling rapid determination of whether its volt-ampere characteristics meet specifications. This effectively prevents defective cores from proceeding to subsequent winding, assembly, and other processes, avoiding unnecessary material and labor waste at the source, and ensuring consistent and reliable product quality.
  • File size: 292.2KB

  • File size: 4.4MB

  • File size: 2.1MB


Product Model

Model

Overview

Product Brochure

ZX2735Test Current: 1 mA–300 mA; Measurement Range: 1 μV–500 mV; Supports sine wave; 2U standard chassis.

Click to View

Functions & Advantages

● Three selectable modes: Average, True RMS, and ABX-7, for multi-purpose use

● Can be used as a low-voltage AC constant current source or an AC millivoltmeter

● Fast measurement speed, high accuracy, and excellent stability

● PASS/FAIL dual-color LED indicators with multi-state buzzer alerts

● Selectable speed and ranges to meet diverse testing requirements

● Simplified Chinese interface, easy to learn and operate

● Automatically saves current test conditions on power-off, no reconfiguration needed on next startup

● Test conditions can be saved as 50 sets internally and 500 sets on USB flash drive

● 14-bin PASS sorting, with HI and LOW limit judgment

 

 

Test Principle

The instrument operates based on the volt-ampere (V-A) method. During testing, a precisely adjustable AC constant current source is applied through the Hcur/Lcur terminals to a coil wound around the DUT core, exciting the core to generate an alternating magnetic field; meanwhile, the induced AC voltage on the core is measured through the Hpot/Lpot terminals. According to Ohm's law Vx = I × Z , with the excitation current I known, the measured voltage Vx directly reflects the equivalent impedance Z of the core at that operating point. Therefore, by comparing whether the induced voltage V falls within the preset range, the volt-ampere characteristics of the core can be judged as acceptable or not.

 

Excitation Output Function

◆  AC Constant Current Source

Output current is continuously adjustable from 1 mA to 300 mA, maintaining 1% current accuracy across the full range, providing stable excitation conditions for core testing.

◆  Excitation Waveform

The ZX2735 supports sine wave, suitable for conventional core volt-ampere characteristic testing and providing a standardized evaluation reference.

◆  Test Frequency

Two test frequencies, 50 Hz and 60 Hz, are selectable, providing standardized excitation for core characteristic evaluation under power frequency conditions and ensuring reliable reference benchmarks for consistency control. 
 

Voltage Measurement Function

◆  AC Millivoltmeter

Minimum resolution of 1 μV, measurement range from 1 μV to 500 mV, voltage accuracy of 1% ± 3 μV, capable of precisely capturing μV-level weak induced signals to meet core volt-ampere characteristic testing requirements.

◆  Four Ranges

Four ranges are available: 500 mV / 200 mV / 20 mV / 3 mV. Select the range closest to the measured signal amplitude to ensure the measurement result falls within the optimal accuracy range.

◆  Measurement Modes

To evaluate instrument performance, it is recommended to use high-end benchtop multimeters from Keysight Technologies or Keithley. Handheld multimeters commonly available on the market generally cannot meet the requirements.

Three modes are selectable: Average (AVG), True RMS, and ABX-7.

Average (AVG): Treats the input waveform as a quasi-sine wave and performs rectified averaging on the AC signal before calculation. This mode is suitable for fast measurement of sinusoidal signals; if the waveform is distorted, the error will be larger. This mode can be selected when comparing with low-end handheld multimeters.

True RMS: Performs root-mean-square calculation on the induced waveform according to the effective value formula, directly calculating and displaying the true effective value of waveforms containing harmonic components. The measurement result is independent of waveform shape. This mode can be selected when comparing with high-end multimeters such as the Keysight 34460A and Keithley 2001.

ABX-7: Uses a non-rectified average value algorithm for compatibility with early instruments. It is not a general-purpose measurement mode and is suitable for specific production line testing standards.

 

Sorting Judgment and Result Output

◆  Multi-State Buzzer Alert Function

Test results have two audible alerts: PASS and FAIL. The sounds differ clearly in frequency, pitch, or rhythm, ensuring quick identification.

◆  Comparator Indicator Lights

Judgment results are displayed via front-panel PASS (green) and FAIL (red) dual-color LED indicators. You can work without looking at the screen, improving work efficiency.

◆  Comparator Function

Provides 14-bin PASS sorting (BIN1–BIN14) along with HI (above upper limit) and LOW (below lower limit) judgment. It can compare measurement results with preset standard values or ranges, display and output judgment results, and also output via EXT I/O.

◆  Deviation Modes

Three deviation modes are provided, allowing users to flexibly choose according to production line judgment requirements.

Parameters & Dimensions

ModelZX2735
Test Frequency50 Hz, 60 Hz
Measurement FunctionSine wave
Measurement Range1 μV to 500 mV
Display Range0.001 mV to 499.99 mV
Test SpeedFast: Approx. 40 meas/sec; Medium: Approx. 20 meas/sec; Slow: Approx. 6 meas/sec
Test Current1 mA to 300 mA, accuracy 1%
Voltage Accuracy1% (±3 μV)
Range Mode500 mV, 200 mV, 20 mV, 3 mV
Function ModeAverage, True RMS, ABX-7
Wide Application RangeCan be used as an AC constant current source and AC millivoltmeter
Deviation ModeDirect read, absolute deviation, coefficient
ComparatorBIN1–BIN14, HI, LOW
PASS, FAIL (LED indicator), Buzzer Alert
Trigger ModeInternal, Manual, External
InterfaceGPIB (optional), RS-232C, USB Host, USB Device, Handler
Memory

Internal: 50 sets

External USB flash drive: 500 sets

Temperature & Humidity0 °C to 40 °C, Relative Humidity ≤ 75%
Power Requirements100 to 120 VAC or 198 to 242 VAC
46 to 64 Hz, Power >50 VA
Dimensions (W × H × D)216 mm × 87 mm × 300 mm
Weight3.2 kg

Unit: millimeters (mm)

Accessories & Options

ZX2736Y02 Test Cable

ZX2736Y02 Test Cable

ZX2735Y01 Test Platform

ZX2735Y01 Test Platform

Software & Resources

Solutions

undefined

undefined

Customer Q&A

Enter information to retrieve data.

By systematically retrieving and analyzing relevant input information, comprehensive and specialized data are obtained to support or meet specific needs or objectives.

Confirm
%{tishi_zhanwei}%