The ZX8533 series precision LCR meters utilize auto-balancing bridge technology and four-terminal pair Kelvin test terminals, with a measurement frequency range covering 20 Hz to 500 kHz, basic measurement accuracy up to 0.05%, and basic stability up to one part in 100,000. Special optimization has been made for the measurement accuracy and stability of extremely low dissipation factor (DF) and very low equivalent series resistance (ESR). It is suitable for measuring current new energy and new materials, such as CBB film capacitors, solid capacitors, DC-Link capacitors, MLCC capacitors, and nH-level inductors like T-CORE molded small inductors. The instrument also features enhanced anti-shock protection at the test terminals and includes a contact check function, which solves the misjudgment issue caused by poor contact in one of the four test leads during automated production line 4-wire measurements — a common problem with similar instruments on the market. It is widely applicable for use in both laboratories and production lines.
  • File size: 11.7MB

  • File size: 607.7KB

  • File size: 3.8MB

  • File size: 3.5MB

  • File size: 3.3MB

  • File size: 3.1MB


Product Model

ModelOverviewProduct Brochure
ZX8533A-01Auto-balancing bridge; Basic Accuracy: ±0.05%; Frequency: 20 Hz–100 kHz; 4.3-inch LCD display; High-speed, high-performance standard version.Click to View
ZX8533A-02Auto-balancing bridge; Basic Accuracy: ±0.05%; Frequency: 20 Hz–200 kHz; 4.3-inch LCD display; High-speed, high-performance standard version.Click to View
ZX8533A-05Auto-balancing bridge; Basic Accuracy: ±0.05%; Frequency: 20 Hz–500 kHz; 4.3-inch LCD display; High-speed, high-performance standard version.Click to View
ZX8533S-01 Auto-balancing bridge; Basic Accuracy: ±0.05%; Frequency: 20 Hz–100 kHz; 4.3-inch LCD display; High-speed, equipment-dedicated simplified interface.Click to View
ZX8533S-02Auto-balancing bridge; Basic Accuracy: ±0.05%; Frequency: 20 Hz–200 kHz; 4.3-inch LCD display; High-speed, equipment-dedicated simplified interface.Click to View
ZX8533S-05Auto-balancing bridge; Basic Accuracy: ±0.05%; Frequency: 20 Hz–500 kHz; 4.3-inch LCD display; High-speed, equipment-dedicated simplified interface.Click to View
ZX8533MGT-01Auto-balancing bridge; Multi-parameter solid capacitor testing; Frequency: 20 Hz–100 kHz; 4.3-inch LCD display.Click to View
ZX8533MGT-02Auto-balancing bridge; Multi-parameter solid capacitor testing; Frequency: 20 Hz–200 kHz; 4.3-inch LCD display.Click to View
ZX8533MGT-05Auto-balancing bridge; Multi-parameter solid capacitor testing; Frequency: 20 Hz–500 kHz; 4.3-inch LCD display.Click to View
ZX8533DFC-01 Auto-balancing bridge; Dual-frequency capacitor testing; Frequency: 20 Hz–100 kHz; 4.3-inch LCD display.Click to View
ZX8533DFC-02 Auto-balancing bridge; Dual-frequency capacitor testing; Frequency: 20 Hz–200 kHz; 4.3-inch LCD display.Click to View
ZX8533DFC-05Auto-balancing bridge; Dual-frequency capacitor testing; Frequency: 20 Hz–500 kHz; 4.3-inch LCD display.Click to View
ZX8533P-01Auto-balancing bridge; Basic Accuracy: ±0.05%; Frequency: 20 Hz–100 kHz; 4.3-inch LCD display; High-precision 7-digit display.Click to View
ZX8533P-02Auto-balancing bridge; Basic Accuracy: ±0.05%; Frequency: 20 Hz–200 kHz; 4.3-inch LCD display; High-precision 7-digit display.Click to View
ZX8533P-05Auto-balancing bridge; Basic Accuracy: ±0.05%; Frequency: 20 Hz–500 kHz; 4.3-inch LCD display; High-precision 7-digit display.Click to View
ZX8533S-HMAuto-balancing bridge; Basic Accuracy: ±0.05%; Frequency: 20 Hz–500 kHz; 4.3-inch LCD display; High-speed, equipment-dedicated simplified interface; Designed for color ring inductor slide testing machine systems.Click to View

Functions & Advantages

● Auto-balancing bridge technology, four-terminal pair Kelvin test terminals

● High precision: basic accuracy 0.05%

● High stability: basic stability 1/100,000

● Contact check function with open-circuit detection capability at test terminals

● Measurement level: 10 mV to 2 Vrms

● Provides internal DC bias: 0 V to +5 V

● Internal resistance: LOW Z, 10 Ω, 30 Ω, 100 Ω

● Sampling time: FAST / MED / SLOW , three selectable modes

● Open, short, and load correction functions

● Test data, test conditions, and screen can be saved (USB flash drive or internal memory)

● Host computer interfaces: RS-232C, USBTMC, USBCDC, RS485 (optional), GPIB (optional), LAN (optional)

● HANDLER interface (CN36) supports 10-bin sorting, with independent HI/LO signal output for primary parameters and independent signal output for secondary parameters, meeting various automation equipment requirements.

 

Auto-Balancing Bridge Test Principle

The traditional simple operational amplifier measurement architecture has been comprehensively upgraded to a vector negative feedback network composed of core modules including the Lpot null detection circuit, 0°/90° digital phase detection and modulation/demodulation circuits, and the Lcur high-frequency drive circuit.

This architectural innovation brings the "virtual ground" terminal of the measurement circuit closer to the ideal state, achieving a qualitative leap in measurement accuracy and anti-interference capability across various practical application scenarios. Whether measuring extremely low dissipation factor (D) of high-capacity energy storage capacitors in the new energy field, or tiny inductance values (L and Q) in high-frequency environments, the ZX8533 handles them with ease, delivering precise measurements.

 

High-Speed, High-Precision, and Wide Guaranteed Accuracy Range

◆  High Speed & High Precision

±0.05% rdg. high precision — deviation is only 1/8 of previous models, with measurement speed up to 5 times faster than conventional instruments, boosting production capacity.

◆  High Speed at Low Frequencies

Thanks to the innovative use of high-speed sampling technology, this instrument maintains high-speed measurement even at low frequencies (e.g., 120 Hz and below), achieving measurement speeds 5 times faster than conventional instruments.

◆  Stable Dissipation Factor Measurement

When measuring the dissipation factor D of CBB film capacitors at 100 kHz and 540 μF DC-Link capacitors at 120 Hz, stability reaches 1/100,000 in both cases.

◆  Stable Low-Voltage Testing for Micro Motors

DCR test level has 2 adjustable settings (1.0 V/0.2 V), suitable for low-voltage testing of micro motors to avoid instability caused by the motor rotating due to the test voltage during measurement.

 

Full-Stack Measurement for the New Energy Industry

◆  Ideal for Measuring Most New Energy Materials

The ZX8533 series employs auto-balancing bridge technology and four-terminal pair Kelvin test terminals, with a measurement frequency range covering 20 Hz to 500 kHz. Basic measurement accuracy reaches 0.05%, and basic stability reaches 1/100,000. Special optimization has been made for the measurement accuracy and stability of extremely low dissipation factor (DF) and ultra-low equivalent series resistance (ESR). It is suitable for measuring current new energy and new materials, such as CBB film capacitors, DC-Link capacitors, T-CORE molded small inductors (nH-level), MLCC capacitors, and solid capacitors.

◆  Significantly Improved Dissipation Factor (D) Measurement Stability

Suitable for measuring the reliability and efficiency of core energy devices such as film capacitors and DC-Link capacitors in new energy power conversion layers. Through precise measurement with the ZX8533, it helps improve the conversion efficiency, power density, and long-term reliability of electric drive systems and photovoltaic inverters, enhancing range and power generation.

◆  Precise nH-Level Small Inductance Measurement

Suitable for measuring the stability and efficiency of high-frequency magnetic components such as T-CORE inductors and high-frequency power transformers in new energy power conversion layers. Through precise measurement with the ZX8533, it ensures the conversion efficiency and dynamic stability of high-frequency switching power supplies like on-board chargers (OBC) and auxiliary power supplies, improving system energy efficiency and EMC performance.

◆  Precise High-Capacitance MLCC Measurement

Suitable for measuring the performance of precision components such as MLCCs and solid capacitors in new energy control and signal layers. Through precise measurement with the ZX8533, it ensures signal integrity and power purity of critical control units such as battery management, motor control, and communication systems, laying a solid reliability foundation for the entire intelligent system.

◆  High-Precision Measurement of Multiple Parameters on a Single Page (Up to 6 Parameters Simultaneously!)

 

Extended Instrument Service Life

◆  Residual Charge Protection Function

To prevent mistakenly connecting a charged capacitor to the measurement port, this instrument innovatively employs enhanced two-stage protection, strengthening the protection of internal circuits against residual charges from capacitor discharge voltage.

 

Avoiding Measurement Signal Crosstalk

◆  Frequency Shift Function

In automated production line testing, when multiple instruments of the same model are integrated to form a measurement system, the frequency shift function can be used to adjust frequencies to avoid interference between measurement signals, thereby improving test accuracy.

 

One ZX8533 Replaces Two Instruments, Simplifying System Structure and Saving Space

◆  Multi-Parameter Function

While measuring power inductor L-Q at 1 kHz, it simultaneously measures DC resistance (DCR). A single ZX8533 enables high-speed continuous measurement of different parameters under different conditions, displaying all results on the same page for convenient observation.

The instrument sequentially reads the configured measurement conditions and continuously measures different parameters under different conditions, supporting up to 6 parameters displayed simultaneously on the  page.

 

Higher Maximum External Current in High-Accuracy Mode

◆  Low Z Mode

In Low Z mode, the output impedance becomes 10 Ω, allowing sufficient current to flow through the DUT, making it suitable for high-precision measurements.

 

Enable ALC for High-Capacitance MLCC Measurement

◆  ALC Function

MLCC capacitance (especially Class II high-dielectric types) varies significantly with test voltage, and the voltage division caused by the LCR's internal output impedance causes the actual voltage to deviate from the set value, resulting in severely low test results and greatly affecting measurement accuracy. When ALC is enabled, the instrument monitors the actual voltage across the MLCC in real time and automatically adjusts the signal source output to maintain a constant AC test voltage, eliminating the voltage division error between the LCR output impedance and the DUT impedance, ensuring test conditions meet specification requirements.

 

Host Computer Communication Software

The ZX8533 series supports remote control and real-time data acquisition through the "ZXP Precision LCR Host Computer General Demo Software," improving measurement efficiency and data traceability for automated production line testing.

Parameters & Dimensions

ModelZX8533A
Test ParametersZ, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tan δ)
Measurement Range100 mΩ to 100 kΩ, 10 ranges (all parameters are specified by Z)
Display Range

Z: 0.00 m to 9.99999 GΩ, Y: 0.000n to 9.99999 GS, θ: ± (0.000° to 999.999°), Q: ± (0.00 to 9999.99),

Rdc: ± (0.00 m to 9.99999 GΩ), D: ± (0.00000 to 9.99999), Δ%: ± (0.000% to 999.999%) etc.

Basic AccuracyZ: 0.05% rdg. θ: 0.03°
Test SpeedFast / Medium / Slow ; Refer to the table below for specific measurement times
Measurement Frequency20 Hz to 500 kHz (measurement frequency varies by model)
Test Signal Level

[V-mode, CV-mode][Normal Mode]

20 Hz to 500 kHz: 10 mV to 2 V (up to 50 mA)

[DC Resistance Measurement]: 1 V fixed

DC Bias VoltageOperating range: DC voltage 0–5 V (0–1 V in low-Z, high-precision mode)
Output ImpedanceLOWZ, 10 Ω, 30 Ω, 100 Ω
DisplayColor TFT 4.3-inch LCD screen
FunctionsComparator, BIN measurement (2 items with 10 bins), trigger function, open-circuit and short-circuit correction, contact check, panel save/recall function, and storage function.
Interface

Handler, USBTMC, USBCDC, USBHOST, RS-232C

LAN (optional), RS485 (optional), GP-IB (optional)

Power SupplyAC 100 to 240 V, 50/60 Hz, 50 VA max
Dimensions   (W × H × D)330 mm × 119 mm × 230 mm
Weight4.2 kg

◆  Appendix: Measurement Time [ms] (DC Bias: OFF)

Speed ModeTest Frequency
20 Hz100 Hz1 kHz10 kHz100 kHz500 kHz
Slow480300240230220220
Medium380180110928988
Fast330100207.75.75.6
 

Unit: millimeters (mm)

Accessories & Options

ZX28Y11AS Four-Terminal Pair (4TP) Test Cable

ZX28Y11AS Four-Terminal Pair (4TP) Test Cable

ZX28Y10

ZX28Y10

ZX26Y01 Kelvin Test Fixture

ZX26Y01 Kelvin Test Fixture

Software & Resources

ZX8533 RS485 ModbusRTU Command Quick Reference Manual – Web Version

2026-10-17

ZX8533 SCPI Command Quick Reference Manual – Web Version

2026-10-13

Zhixin Precision LCR PC General Demo Software Installer

2026-07-20

ZX8533A vs E4980AL Selection Comparison Table

2026-05-13

Customer Q&A

Q: What are the specific differences between the ZX8533A and the Keysight E4980AL across four key dimensions: technical specifications, functional features, application value, and total cost of ownership (TCO)?

A: The ZX8533A differs from the E4980AL in aspects such as measurement speed, output impedance, multi-parameter display, and interface protocols. For example, the ZX8533A offers a 10 Ω low-impedance mode, simultaneous display of up to 6 parameters, USBHID plug-and-play data upload, and supports the Modbus RTU industrial protocol. Total cost of ownership (TCO) also differs between the two. For details, please refer to the document "ZX8533A vs E4980AL Selection Comparison Table" (PDF).

(Note: This comparison is compiled from publicly available information from both parties. It does not contain any derogatory statements and is intended solely to save engineers time in conducting their own research, facilitating quick reference for model selection.)

Q: In multi-parameter measurement mode, there is an "H" or "L" displayed after the setting, and the result keeps showing NG. What is the cause?

A: This indicates that the measured value falls outside the upper or lower limits of the set nominal value — either exceeding the upper limit (H) or falling below the lower limit (L). Please carefully review the limit settings for each parameter in the multi-parameter configuration.

Q: Why is there a deviation in the data on the multi-parameter measurement page?

A: The multi-parameter page requires separate zeroing. On the multi-parameter measurement page, press the numeric key 1 (for short zeroing) or 0 (for open zeroing), then press the Trigger key to perform zeroing. Please ensure that the test fixture is in a reliable short or open state before zeroing.

Q: Why does the instrument not alarm on defective products, or why does it keep beeping constantly?

A: ▪ Make sure the upper/lower limits and nominal value are configured, and that the comparator is turned ON.
   ▪ Check the beep settings under "System". Set "Pass Beep" and "Fail Beep" to the desired mode.

Q: Why do the readings fluctuate significantly and become unstable during zeroing?

A: When shorting the clips, ensure that the corresponding color-matched clips (red-to-blue and black-to-white) are clipped on the same side.

Q: When connecting to a PLC, the instrument output signal is found to be invalid. How can this be resolved?

A: The Handler interface output mode is set to "Hold" by default. You can change it to "Delay Clear" or "Start Clear" mode.

Q: Why do the measured values differ significantly from the standard values?

A: ▪ Check whether the short-circuit reading (pay attention to the clip connection method) is near 0 mΩ. Re-zero the instrument whenever the test environment changes, such as after replacing the fixture or test leads.

   ▪ Check whether compensation has been applied. Try disabling compensation and re-zeroing.

   ▪ If the test leads are long, have multiple adapters, or are aged, inspect all four test leads for open circuits or poor contact.

   ▪ Verify that the instrument's range matches the DUT. A large range mismatch can cause measurement errors.

Total 7 < 1 >

Enter information to retrieve data.

By systematically retrieving and analyzing relevant input information, comprehensive and specialized data are obtained to support or meet specific needs or objectives.

Confirm
%{tishi_zhanwei}%