ZX1376 Series DC Bias Current Source & LCR Meter with DC Bias Current Source

The ZX1376X is an LCR meter with DC bias current source, featuring a built-in high-frequency LCR meter and a 0–25 A DC bias current source. With a current resolution as fine as 0.25 mA and an output voltage of up to 11 V at 25 A, it can analyze the characteristics of inductor cores, making it ideal for inductor quality inspection or product characteristic analysis. Its built-in bias source offers lower noise and more flexible control. Additionally, the integrated comparator facilitates seamless integration into automated inductor testing production lines. The ZX1376 model consists solely of a 0–25 A DC bias current source, which can be easily connected to an external LCR meter via a standard RS-232C interface.
  • File size: 5.6MB

  • File size: 243.8KB


Product Model

Model

Overview

Product Brochure

ZX1376-25 AStandalone 25 A DC bias current source; not expandable.

Click to View

ZX1376X-25 ABuilt-in LCR meter; 50 Hz–200 kHz, 10 mV–2 V; Includes 25 A DC bias current source; not expandable.Click to View
ZX1376AX-25 ABuilt-in LCR meter; 50 Hz–300 kHz, 10 mV–2 V; Includes 25 A DC bias current source; not expandable.Click to View
ZX1376BX-25 ABuilt-in LCR meter; 50 Hz–500 kHz, 10 mV–2 V; Includes 25 A DC bias current source; not expandable.Click to View
ZX1376CX-25 ABuilt-in LCR meter; 50 Hz–1 MHz, 10 mV–2 V; Includes 25 A DC bias current source; not expandable.Click to View

 

Functions & Advantages

● Provides 0 to 25 A constant current output per unit

● 0.25 mA fine current step

● 2 MHz frequency response

● Single current and step sweep current output modes

● Graphical operation, Chinese/English interface

● Can be controlled by an external LCR meter via RS-232C interface using SCPI commands

 

Main Functions

◆  Wide output range and fine current steps

ZX1373 (0 to 12 A), ZX1376/ZX1379 (0 to 25 A), stackable up to 8 slave units for 225 A total. Minimum step 0.25 mA, dense sampling in the saturation region, accurately constructing inductance vs. bias current curves.

◆  Two current output modes

Single current mode: fixed current, suitable for routine inspection. Step sweep mode: preset current sequence for automatic sweeping, intuitively judging component quality by the rate of inductance decrease.

◆  Bias current output duration

Settable from 0 to 3600 seconds; bias output automatically turns off when the set time is reached (set to 0 for continuous output). Prevents device overheating, suitable for production lines with strict control over test duration.

◆  Auto current continuation

When changing DUTs, the current is automatically adjusted to near 0 A without turning off the bias; it restores once the DUT is re-clamped. No manual start/stop required, improving mass testing efficiency.

◆  Open/short correction

To eliminate parasitic parameter errors introduced by test fixtures and connecting cables, ensuring measurement results truly reflect DUT characteristics.

 

Typical Applications

◆  Current saturation performance testing

Using the "Changzhou ZhiXin Inductor DC Bias Characteristic Analysis PC Software," measurement data and curve graphics are displayed intuitively, generating inductance vs. bias current characteristic curves and accurately calibrating the saturation limited current.

◆  Temperature rise current testing

Based on the collaborative operation of the inductor superimposed current source and the temperature tester, the dynamic characteristic curve of inductor temperature rise versus current can be collected and recorded in real time, accurately presenting the correspondence between temperature and current, thereby accurately calibrating the temperature rise limited current.

Parameters & Dimensions

ModelZX1376-25 AZX1376X-25 A
Display7" LCD7" LCD
OperationPhysical Buttons + Foot SwitchPhysical Buttons + Foot Switch
Supports Measurement Frequencyup to 2 MHz
Current Range0–25 A
CurrentRange0 mA to 1.000 A, 1.000 A to 5.000 A, 5.0 A to 25 A
Step0.25 mA, 1.25 mA, 6.25 mA
Precision±(1% + 5 mA), ±2%, ±3%
Max Output Voltage11 V (Can output 11 V under all current conditions!!!)
Max Allowed DC ResistanceRmax = Vmax / I (Ω) (Refer to the user manual for Rmax calculation details)
Max Allowed InductanceLmax = Vmax / (di/dt) (mH) (Refer to the user manual for Lmax calculation details)
Range ModeAuto
Start/Stop Control ModeSTART/STOP Physical Button, 4 Type of Foot Controls, Bus
Max Continuous Current Load TimeConservative 2–3 hours, uninterrupted output
FunctionsInstrument fault self-test; 99 groups of custom file management; Dual progress bar indication; Chinese/English bilingual; Slave soft switch; Real-time operation; SCPI command set; Simple dual-display calculator, etc.
InterfaceSlaverLink, RS-232C, USB Host, USB Device, Handler, GPIB (optional)
Power RequirementsVoltage: 100 to 120 VAC or 198 to 242 VAC
Frequency: 46 to 64 Hz, Power >50 VA
Temperature & Humidity0 °C to 40 °C, Relative Humidity ≤ 75%
Dimensions (W × H × D)433.5 mm × 177 mm × 464.2 mm
Weight (net weight)19 kg

 

ModelZX1376X-25 AZX1376AX-25 AZX1376BX-25 AZX1376CX-25 A
Test Frequency50 Hz to 200 kHz50 Hz to 300 kHz50 Hz to 500 kHz50 Hz to 1 MHz
More than 12,000 frequency points
Test ParametersC, L, X, B, R, G, D, Q, ESR, Rp, θ, |Z|, |Y|
Test Level10 mV-2 Vrms
Basic Accuracy0.05%, refer to accuracy table
Test Speed

Fast: 50 meas/sec, Medium: 20 meas/sec, Slow: 6 meas/sec

(Frequencies above 1 kHz)

Display Range|Z|, R, X0.01 mΩ to 99.9999 MΩ
|Y|, G, B0.00001 μS to 99.9999 S
C0.00001 pF to 9.99999 F
D0.00001 to 9.99999
DCR0.01 mΩ to 99.9999 MΩ
L0.00001 μH to 99999.9 H
Q0.01 to 99999.9
θ(RAD)-3.14159 to 3.14159
θ(DEG)-179.999° to 179.999°
Δ%-99.999% to 99.999%
Signal Source Output Impedance30 Ω, 100 Ω, 1062X
Range ModeAuto, Hold
Trigger ModeInternal, Manual, Auto, External, Bus
Correction FunctionOpen/Short, All-frequency zeroing, Spot-frequency zeroing
Equivalent CircuitSeries, Parallel
Comparator10-bin sorting, BIN0–BIN9
PASS, HI, LOW (PASS/FAIL LED indication)

 

Unit: millimeters (mm)

Accessories & Options

ZX1375Y03 Test Cable

ZX1375Y03 Test Cable

ZX28Y11 Four-Terminal Kelvin Test Cable

ZX28Y11 Four-Terminal Kelvin Test Cable

Software & Resources

Solutions

undefined

undefined

Customer Q&A

Q: Why does the instrument display a "BIAS OVER" error?

A: This is typically caused by an open circuit in the test leads, preventing the loop from being properly formed. It may also be due to the internal resistance of the DUT being too high.

Q: Why does the instrument fail to alarm when a defective product is detected, or why does it keep alarming continuously?

A: ▪ Check whether the upper/lower limits and nominal value have been set, and ensure the comparator function is enabled.

   ▪ Check the beep settings under "System" → "Test Configuration". Set "Pass Beep" and "Fail Beep" to the desired mode.

Q: The reading fluctuates significantly when the instrument applies bias current. How can this be resolved?

A: ▪ Check whether the test leads are making reliable contact with the DUT.

   ▪ Check the instrument's internal resistance setting. Try changing it to 30 Ω or refer to the 1062X series for comparison.

Q: Why do the readings fluctuate significantly and become unstable during zeroing?

A: When shorting the clips, ensure that the corresponding color-matched clips (red-to-blue and black-to-white) are clipped on the same side.

Q: When connecting to a PLC, the instrument output signal is found to be invalid. How can this be resolved?

A: The Handler interface output mode is set to "Hold" by default. You can change it to "Delay Clear" or "Start Clear" mode.

Q: Why do the measured values differ significantly from the standard values?

A: ▪ Check whether the short-circuit reading (pay attention to the clip connection method) is near 0 mΩ. Re-zero the instrument whenever the test environment changes, such as after replacing the fixture or test leads.

   ▪ Check whether compensation has been applied. Try disabling compensation and re-zeroing.

   ▪ If the test leads are long, have multiple adapters, or are aged, inspect all four test leads for open circuits or poor contact.

   ▪ Verify that the instrument's range matches the DUT. A large range mismatch can cause measurement errors.