ZX8517CX Common Mode Choke Balance Tester

The ZX8517CX series common mode choke/transformer balance testers are specifically designed for efficient comparative testing of balanced components. With a single clamping action, the instrument automatically completes dual-winding (L1/L2) inductance measurement, balance calculation, and PASS/FAIL judgment — eliminating the need for two separate measurements and manual calculations required by traditional LCR meters, significantly simplifying the test process and greatly improving production efficiency. The CX series offers a basic accuracy of up to 0.05% and integrates turns ratio measurement capability, supporting testing of both 2-winding and 3-winding devices. Multiple parameters including Ls, DCR, turns ratio, and balance are displayed simultaneously on one screen, presenting test results in a centralized view that balances efficiency with information completeness.
  • File size: 354.5KB

  • File size: 5.6MB

  • File size: 404.3KB


Product Model

Model

Overview

Product Brochure

ZX8517CX-4PABasic Accuracy: ±0.05%; Frequency: 50 Hz–200 kHz, 37 points; Supports 2-winding testing and turns ratio measurement.

Click to View

ZX8517CX-6PABasic Accuracy: ±0.05%; Frequency: 50 Hz–200 kHz, 37 points; Supports 3-winding testing and turns ratio measurement.

Click to View

Functions & Advantages

● 0.1% test accuracy, fast measurement speed (up to 40 meas/sec)

● High cost-effectiveness, ideal for balanced component testing.

● Pass/Fail LED indicators and buzzer alarm

● Supports USB flash drive upgrades, measurement data can be quickly saved to USB.

● Test condition storage: 100 sets internally, 500 sets on USB flash drive

● Simplified Chinese and English operation languages, easy to use.

● Key lock function; automatically saves test conditions on power-off

● Easy PC connection for data recording, saving, and processing

● Multiple internal resistance modes available

 

Multifunctional Support for Reliable Measurements

◆  Correction and Compensation Function

Supports all-frequency zeroing, spot-frequency zeroing, and cable compensation, with independent AC and DC correction, effectively eliminating errors introduced by fixtures, cables, and system parasitics.

◆  Averaging Function

Configurable averaging from 1 to 255 readings, effectively filtering random noise and improving measurement consistency.

◆  Trigger Delay Function

Programmable trigger delay ensures measurements are taken after the test signal has stabilized, preventing reading fluctuations caused by insufficient settling time.

 

Dual-Mode Operation for Versatile Testing

◆  Balance Measurement Mode

In this default mode, a single clamping action automatically completes dual-unit measurement, balance calculation, and PASS/FAIL judgment — eliminating manual recording and arithmetic operations for efficient batch testing on production lines.

◆  Single Measurement Mode

Switching to this mode allows detailed parameter measurement (L, R, Q, |Z|, etc.) for each unit, suitable for R&D parameter validation, material evaluation, and production line failure analysis — expanding the instrument's application depth.

 

User-Friendly Design for Enhanced Test Experience

◆  Data Logging and Export

Both test data and screen captures can be saved to a USB flash drive with one click for quality traceability and data archiving — no PC connection required.

◆  System Upgrade Without Return to Factory

The instrument supports system software upgrades via USB flash drive, eliminating the need to return the unit to the factory for the latest features and optimizations — reducing maintenance costs and downtime.

◆  File Management Function

The CX series stores up to 100 test setup files internally and 500 on an external USB flash drive. One-click recall during production changeovers reduces repetitive setup time.

◆  Audible and Visual Alarm for Defective Products

Multi-state buzzer function: PASS and FAIL can be independently configured with distinct tones, with clear differences in frequency, pitch, or rhythm for quick identification.

Comparator indicator lights: Red/green LEDs display judgment results, allowing operation without looking at the screen for improved efficiency.

◆  Key Lock Function

Prevents accidental modification of configured parameters, avoiding test anomalies caused by unintended operations.

 

Automated Production Line Integration

◆  High-Speed Automated Judgment

The CX series delivers up to 50 meas/sec (single parameter, single test) with range lock function, reducing per-unit test time and increasing throughput for batch production line inspection.

◆  Comparator Function

Automatically judges test results against set upper/lower limits, displaying and outputting the judgment results. Output is also available via the HANDLER interface.

◆  HANDLER Sorting Interface

Equipped with RS-232C, USBTMC, USBCDC, USBHID, and optional GPIB. SCPI command set support enables PC/PLC remote control and data acquisition.

◆  Multiple Communication Interfaces

These interfaces enable the formation of automated test systems, outputting binning comparison results and handshake signals while receiving external start signals.

 

Multi-Parameter Display on One Screen

A single measurement simultaneously provides multiple parameters including Ls, DCR, turns ratio, balance, and more — all displayed on one screen without the need for page switching.

 

Configurable Sweep Mode

Supports both SEQ and STEP sweep modes for flexible adaptation to different test workflow requirements.

 

Offset Cancellation Function

Supports offset cancellation for Lx, DCR, TURN, and Cx parameters, automatically eliminating systematic errors from test results.

 

Nominal Value Load Function

Allows the current measurement result to be loaded into the selected nominal value slot with one click, overwriting the existing nominal value. This operation is only available if the slot already has a nominal value set.

 

Fail Stop / Continue

Configurable to stop testing the current DUT and mark it as FAIL when a parameter exceeds the limit, or to continue completing all parameter tests to obtain full data for failure analysis.

Parameters & Dimensions

ModelZX8517CX-4PAZX8517CX-6PA
Test Frequency50 Hz to 200 kHz, 37 typical frequency points
Test ParametersL, R, Q, |Z|, θ(RAD), C, DCR
Test Pins4 PIN6 PIN
Basic Accuracy0.05%, refer to the accuracy table0.05%, refer to the accuracy table
Test SpeedFast: 50 meas/sec, Medium: 20 meas/sec, Slow: 6 meas/sec
Test Level50 mV–2.0 V, Continuously Adjustable
Signal Source Impedance30 Ω, 50 Ω, 100 Ω, 10 / 100 Ω
Range ModeAuto, Hold
Trigger ModeInternal, Manual, Auto, External, Bus
Correction FunctionOpen/Short, All-frequency zeroing, Spot-frequency zeroing
Test Box Balancing FixtureStandardNone
Display Range|Z|0.1 mΩ to 99.999 MΩ0.1 mΩ to 99.999 MΩ
L0.0001 μH to 999.99 H0.0001 μH to 9999.9 H
R0.01 mΩ to 99.999 MΩ0.1 mΩ to 99.999 MΩ
Q0.1 to 9999.90.1 to 9999.9
C0.0001 pF to 9999.9 F0.0001 pF to 9999.9 F
θ(RAD)-3.14159 to 3.14159-3.14159 to 3.14159
θ(DEG)-179.99° to 179.99°-179.99° to 179.99°
Δ%-99.999% to 99.999%-99.999% to 99.999%
DCR0.01 mΩ - 99.9999 MΩ0.01 mΩ - 99.9999 MΩ
Equivalent CircuitSeries, Parallel
ComparatorPASS, HI, LOW (PASS/FAIL LED indication)
InterfaceGPIB (optional)
RS-232C, USB Host, USB Device, Handler
MemoryInternal: 100 sets; External USB flash drive: 50 sets
Temperature & Humidity0 °C to 40 °C, Relative Humidity ≤ 75%
Power Requirements100 to 120 VAC or 198 to 242 VAC
46 to 64 Hz, Power >50 VA
Dimensions (W × H × D)310 mm × 110 mm × 315 mm
Weight (net weight)5.5 kg

Unit: millimeters (mm)

Accessories & Options

ZX28Y11 Four-Terminal Kelvin Test Cable

ZX28Y11 Four-Terminal Kelvin Test Cable

ZX28Y04B Two-terminal test cable

ZX28Y04B Two-terminal test cable

ZX28Y34 DB9 Control Cable (Male, 1-to-1)

ZX28Y34 DB9 Control Cable (Male, 1-to-1)

ZX2816Y Test Box

ZX2816Y Test Box

Software & Resources

Solutions

undefined

undefined

Customer Q&A

Q: After the pin positions are set on the instrument, all measured values are incorrect when a product is placed. What is the cause?

A: ▪ The scanner box requires a 232 direct-connection cable to operate.

    ▪ Check the fixture pin positions on the scanner box, and ensure that the product pins correspond one-to-one with the fixture pins.

Q: The instrument does not alarm when a defective product is detected, or the instrument keeps alarming. What is the cause?

A: ▪ Check whether the upper/lower limits and nominal value have been set, and confirm that the comparator function is enabled.

    ▪ Check the buzzer settings: locate "Pass Beep" and "Fail Beep" under System, and change them to the desired mode.

Q: The trigger mode has been changed to auto trigger, but the instrument still does not perform a test after a product is placed. What is the cause?

A: You need to increase the value of the "Auto Trigger Z" setting under System – Test Configuration.