ZX8517CX Common Mode Choke Balance Tester
Category:
-
File size: 354.5KB
-
File size: 5.6MB
-
File size: 404.3KB
Product Model
Model | Overview | Product Brochure |
| ZX8517CX-4PA | Basic Accuracy: ±0.05%; Frequency: 50 Hz–200 kHz, 37 points; Supports 2-winding testing and turns ratio measurement. | |
| ZX8517CX-6PA | Basic Accuracy: ±0.05%; Frequency: 50 Hz–200 kHz, 37 points; Supports 3-winding testing and turns ratio measurement. |
Functions & Advantages
● 0.1% test accuracy, fast measurement speed (up to 40 meas/sec) ● High cost-effectiveness, ideal for balanced component testing. ● Pass/Fail LED indicators and buzzer alarm | ● Supports USB flash drive upgrades, measurement data can be quickly saved to USB. ● Test condition storage: 100 sets internally, 500 sets on USB flash drive ● Simplified Chinese and English operation languages, easy to use. | ● Key lock function; automatically saves test conditions on power-off ● Easy PC connection for data recording, saving, and processing ● Multiple internal resistance modes available |
Multifunctional Support for Reliable Measurements
◆ Correction and Compensation Function
Supports all-frequency zeroing, spot-frequency zeroing, and cable compensation, with independent AC and DC correction, effectively eliminating errors introduced by fixtures, cables, and system parasitics.

◆ Averaging Function
Configurable averaging from 1 to 255 readings, effectively filtering random noise and improving measurement consistency.
◆ Trigger Delay Function
Programmable trigger delay ensures measurements are taken after the test signal has stabilized, preventing reading fluctuations caused by insufficient settling time.

Dual-Mode Operation for Versatile Testing
◆ Balance Measurement Mode
In this default mode, a single clamping action automatically completes dual-unit measurement, balance calculation, and PASS/FAIL judgment — eliminating manual recording and arithmetic operations for efficient batch testing on production lines.
◆ Single Measurement Mode
Switching to this mode allows detailed parameter measurement (L, R, Q, |Z|, etc.) for each unit, suitable for R&D parameter validation, material evaluation, and production line failure analysis — expanding the instrument's application depth.
User-Friendly Design for Enhanced Test Experience
◆ Data Logging and Export
Both test data and screen captures can be saved to a USB flash drive with one click for quality traceability and data archiving — no PC connection required.
◆ System Upgrade Without Return to Factory
The instrument supports system software upgrades via USB flash drive, eliminating the need to return the unit to the factory for the latest features and optimizations — reducing maintenance costs and downtime.
◆ File Management Function
The CX series stores up to 100 test setup files internally and 500 on an external USB flash drive. One-click recall during production changeovers reduces repetitive setup time.

◆ Audible and Visual Alarm for Defective Products
Multi-state buzzer function: PASS and FAIL can be independently configured with distinct tones, with clear differences in frequency, pitch, or rhythm for quick identification.
Comparator indicator lights: Red/green LEDs display judgment results, allowing operation without looking at the screen for improved efficiency.
◆ Key Lock Function
Prevents accidental modification of configured parameters, avoiding test anomalies caused by unintended operations.

Automated Production Line Integration
◆ High-Speed Automated Judgment
The CX series delivers up to 50 meas/sec (single parameter, single test) with range lock function, reducing per-unit test time and increasing throughput for batch production line inspection.

◆ Comparator Function
Automatically judges test results against set upper/lower limits, displaying and outputting the judgment results. Output is also available via the HANDLER interface.

◆ HANDLER Sorting Interface
Equipped with RS-232C, USBTMC, USBCDC, USBHID, and optional GPIB. SCPI command set support enables PC/PLC remote control and data acquisition.
◆ Multiple Communication Interfaces
These interfaces enable the formation of automated test systems, outputting binning comparison results and handshake signals while receiving external start signals.
Multi-Parameter Display on One Screen
A single measurement simultaneously provides multiple parameters including Ls, DCR, turns ratio, balance, and more — all displayed on one screen without the need for page switching.

Configurable Sweep Mode
Supports both SEQ and STEP sweep modes for flexible adaptation to different test workflow requirements.

Offset Cancellation Function
Supports offset cancellation for Lx, DCR, TURN, and Cx parameters, automatically eliminating systematic errors from test results.

Nominal Value Load Function
Allows the current measurement result to be loaded into the selected nominal value slot with one click, overwriting the existing nominal value. This operation is only available if the slot already has a nominal value set.

Fail Stop / Continue
Configurable to stop testing the current DUT and mark it as FAIL when a parameter exceeds the limit, or to continue completing all parameter tests to obtain full data for failure analysis.

Parameters & Dimensions
| Model | ZX8517CX-4PA | ZX8517CX-6PA | |
| Test Frequency | 50 Hz to 200 kHz, 37 typical frequency points | ||
| Test Parameters | L, R, Q, |Z|, θ(RAD), C, DCR | ||
| Test Pins | 4 PIN | 6 PIN | |
| Basic Accuracy | 0.05%, refer to the accuracy table | 0.05%, refer to the accuracy table | |
| Test Speed | Fast: 50 meas/sec, Medium: 20 meas/sec, Slow: 6 meas/sec | ||
| Test Level | 50 mV–2.0 V, Continuously Adjustable | ||
| Signal Source Impedance | 30 Ω, 50 Ω, 100 Ω, 10 / 100 Ω | ||
| Range Mode | Auto, Hold | ||
| Trigger Mode | Internal, Manual, Auto, External, Bus | ||
| Correction Function | Open/Short, All-frequency zeroing, Spot-frequency zeroing | ||
| Test Box Balancing Fixture | Standard | None | |
| Display Range | |Z| | 0.1 mΩ to 99.999 MΩ | 0.1 mΩ to 99.999 MΩ |
| L | 0.0001 μH to 999.99 H | 0.0001 μH to 9999.9 H | |
| R | 0.01 mΩ to 99.999 MΩ | 0.1 mΩ to 99.999 MΩ | |
| Q | 0.1 to 9999.9 | 0.1 to 9999.9 | |
| C | 0.0001 pF to 9999.9 F | 0.0001 pF to 9999.9 F | |
| θ(RAD) | -3.14159 to 3.14159 | -3.14159 to 3.14159 | |
| θ(DEG) | -179.99° to 179.99° | -179.99° to 179.99° | |
| Δ% | -99.999% to 99.999% | -99.999% to 99.999% | |
| DCR | 0.01 mΩ - 99.9999 MΩ | 0.01 mΩ - 99.9999 MΩ | |
| Equivalent Circuit | Series, Parallel | ||
| Comparator | PASS, HI, LOW (PASS/FAIL LED indication) | ||
| Interface | GPIB (optional) | ||
| RS-232C, USB Host, USB Device, Handler | |||
| Memory | Internal: 100 sets; External USB flash drive: 50 sets | ||
| Temperature & Humidity | 0 °C to 40 °C, Relative Humidity ≤ 75% | ||
| Power Requirements | 100 to 120 VAC or 198 to 242 VAC | ||
| 46 to 64 Hz, Power >50 VA | |||
| Dimensions (W × H × D) | 310 mm × 110 mm × 315 mm | ||
| Weight (net weight) | 5.5 kg | ||

Unit: millimeters (mm)
Accessories & Options
ZX28Y11 Four-Terminal Kelvin Test Cable
ZX28Y04B Two-terminal test cable
ZX28Y34 DB9 Control Cable (Male, 1-to-1)
ZX2816Y Test Box
Software & Resources
Solutions
undefined
Customer Q&A
Q: After the pin positions are set on the instrument, all measured values are incorrect when a product is placed. What is the cause?
A: ▪ The scanner box requires a 232 direct-connection cable to operate.
▪ Check the fixture pin positions on the scanner box, and ensure that the product pins correspond one-to-one with the fixture pins.
Q: The instrument does not alarm when a defective product is detected, or the instrument keeps alarming. What is the cause?
A: ▪ Check whether the upper/lower limits and nominal value have been set, and confirm that the comparator function is enabled.
▪ Check the buzzer settings: locate "Pass Beep" and "Fail Beep" under System, and change them to the desired mode.
Q: The trigger mode has been changed to auto trigger, but the instrument still does not perform a test after a product is placed. What is the cause?
A: You need to increase the value of the "Auto Trigger Z" setting under System – Test Configuration.