ZX7575BX/ZX7576BX/ZX1085BX Common Mode Choke Balance Tester

The ZX-BX series common mode choke/filter balance testers are specifically designed for efficient comparative testing of balanced components. With a single clamping action, the instrument automatically completes dual-winding (L1/L2) inductance measurement, balance calculation, and PASS/FAIL judgment — eliminating the need for two separate measurements and manual calculations required by traditional LCR meters, significantly simplifying the test process and greatly improving production efficiency. Two modes are available to address different testing needs: In Balance Mode, the instrument automatically outputs PASS/FAIL judgment results; in Single Measurement Mode, detailed parameters such as L, R, Q, and |Z| for each unit can be obtained individually. The two modes are freely switchable, eliminating the need for multiple instruments — saving equipment, space, and cost.
  • File size: 366.9KB

  • File size: 6.0MB

  • File size: 1.1MB


Product Model

Model

Overview

Product Brochure

ZX1085BXBasic Accuracy: ±0.1%; Frequency: 50 Hz–200 kHz, 46 points; Test Level: 10 mV–1 V.

Click to View

ZX7575BXBasic Accuracy: ±0.1%; Frequency: 100 Hz, 120 Hz, 1 kHz, 10 kHz; Test Level: 0.1 V, 0.3 V, 1.0 V.

Click to View

ZX7576BXBasic Accuracy: ±0.1%; Frequency: 50 Hz–100 kHz, 34 points; Test Level: 0.1 V, 0.3 V, 1.0 V.

Click to View

Functions & Advantages

● 0.1% test accuracy, fast measurement speed (40 meas/sec) 

● High cost-effectiveness (includes standalone test function, dual-purpose), the best choice for balanced component testing. 

● Pass/Fail LED indicators and buzzer alarm

● Supports USB flash drive upgrades, measurement data can be quickly saved to USB. 

● Test condition storage: 50 sets internally, 500 sets on USB flash drive 

● Simplified Chinese and English operation languages, easy to use.

● Key lock function; automatically saves test conditions on power-off 

● Easy PC connection for data recording, saving, and processing 

● Multiple internal resistance modes available


Multifunctional Support for Reliable Measurements
 

◆  Open/Short Zeroing Function

Supports all-frequency and spot-frequency zeroing, with separate correction for AC measurement and DC resistance measurement, effectively eliminating errors introduced by test fixtures and cables.

◆  Averaging Function

Configurable averaging from 1 to 255 readings, effectively filtering random noise and improving measurement consistency.

◆  Trigger Delay Function

Programmable trigger delay ensures measurements are taken after the test signal has stabilized, preventing reading fluctuations caused by insufficient settling time.

 

Dual-Mode Operation for Versatile Testing

◆  Balance Measurement Mode

In this default mode, a single clamping action automatically completes dual-unit measurement, balance calculation, and PASS/FAIL judgment — eliminating manual recording and arithmetic operations for efficient batch testing on production lines.

◆  Single Measurement Mode

Switching to this mode allows detailed parameter measurement (L, R, Q, |Z|, etc.) for each unit, suitable for R&D parameter validation, material evaluation, and production line failure analysis — expanding the instrument's application depth.

 

User-Friendly Design for Enhanced Test Experience

◆  Data Logging and Export

Both test data and screen captures can be saved to a USB flash drive with one click for quality traceability and data archiving — no PC connection required.

◆  System Upgrade Without Return to Factory

The instrument supports system software upgrades via USB flash drive, eliminating the need to return the unit to the factory for the latest features and optimizations — reducing maintenance costs and downtime.

◆  File Management Function

The BX series stores up to 50 test setup files internally and 500 on an external USB flash drive. One-click recall during production changeovers reduces repetitive setup time.

◆  Audible and Visual Alarm for Defective Products

Multi-state buzzer function: PASS and FAIL can be independently configured with distinct tones, with clear differences in frequency, pitch, or rhythm for quick identification.

Comparator indicator lights: Red/green LEDs display judgment results, allowing operation without looking at the screen for improved efficiency.

◆  Key Lock Function

Prevents accidental modification of configured parameters, avoiding test anomalies caused by unintended operations.

 

Automated Production Line Integration

◆  High-Speed Automated Judgment

The BX series delivers up to 40 meas/sec (single parameter, single test) with range lock function, reducing per-unit test time and increasing throughput for batch production line inspection.

◆  Comparator Function

Automatically judges test results against set upper/lower limits, displaying and outputting the judgment results. Output is also available via the HANDLER interface.

◆  HANDLER Sorting Interface

Equipped with RS-232C, USBTMC, USBCDC, USBHID, and optional GPIB. SCPI command set support enables PC/PLC remote control and data acquisition.

◆  Multiple Communication Interfaces

These interfaces enable the formation of automated test systems, outputting binning comparison results and handshake signals while receiving external start signals.

 

Four-Terminal Kelvin Measurement

Independent source and sense terminals effectively eliminate errors caused by contact resistance and cable impedance, ensuring accuracy and repeatability in low-impedance measurements.

Parameters & Dimensions

ModelZX1085BXZX7575BXZX7576BX
Test Frequency50 Hz to 200 kHz, 46 points100 Hz, 120 Hz, 1 kHz, 10 kHz50 Hz to 100 kHz, 34 points
Test ParametersL, R, Q, |Z|, DCR, θL, R, Q, |Z|, θ
Test SpeedFast: 40 meas/sec, Medium: 20 meas/sec, Slow: 6 meas/sec
Test Level10 mV to 1 Vrms0.1 Vrms, 0.3 Vrms, 1.0 Vrms
Signal Source Impedance

30 Ω, 100 Ω, 10 / 100 Ω,

10 Ω/CC, 50 Ω

30 Ω, 100 Ω
Basic Accuracy0.1%, refer to the accuracy table
Range ModeAuto, Hold
Trigger ModeInternal, Manual, Auto, External, Bus
Correction FunctionOpen/Short, All-frequency zeroing, Spot-frequency zeroing
Test Box Balancing FixtureTest Box Balancing Fixture or custom cable

 

 

 

 

 

Display Range

|Z|0.1 mΩ to 99.999 MΩ0.1 mΩ to 99.999 MΩ
L0.0001 μH to 999.99 H0.0001 μH to 9999.9 H
R0.01 mΩ to 99.999 MΩ0.1 mΩ to 99.999 MΩ
Q0.1–9999.90.1–9999.9
θ(RAD)-3.14159 to 3.14159-3.14159 to 3.14159
θ(DEG)-179.99° to 179.99°-179.99° to 179.99°
Δ%-99.999% to 99.999%-99.999% to 99.999%
Equivalent CircuitSeries, Parallel

 

Comparator

BIN0–BIN3, NG, AUX
PASS, HI, LOW (PASS/FAIL LED indication)

 

Interface

GPIB (optional)
RS-232C, USB Host, USB Device, Handler
Memory

Internal: 50 sets 

External USB flash drive: 500 sets

Temperature & Humidity0 °C to 40 °C, Relative Humidity ≤ 75%
Power RequirementsVoltage: 100 to 120 VAC or 198 to 242 VAC
Frequency: 46 to 64 Hz, Power >50 VA
Dimensions (W × H × D)310 mm × 110 mm × 315 mm
Weight (net weight)5.5 kg

 

Unit: millimeters (mm)

Accessories & Options

ZX28Y04 Kelvin Test Cable

ZX28Y04 Kelvin Test Cable

ZX75BXY01 Test Box

ZX75BXY01 Test Box

Software & Resources

Solutions

undefined

undefined

Customer Q&A

Q: The instrument is set to auto-trigger mode, but why does it still not trigger when the DUT is placed?

A: The instrument triggers based on impedance detection. If the DUT impedance exceeds the auto-trigger threshold, triggering will not occur. Navigate to [System Interface] → [Test Configuration], locate the "Z≤xxkΩ" setting, and increase the value appropriately.

Q: Why do the values measured by the instrument differ from those measured by other instruments?

A: Pay attention to the instrument's output impedance setting. Different output impedance settings will lead to different measurement results.

Q: The upper and lower limits have been set, but why does the instrument not output PASS or FAIL after measurement?

A: Enter the settings menu and change the "Comparator" function from OFF to ON.