Product Categories
ZX7575BX/ZX7576BX/ZX1085BX Common Mode Choke Balance Tester
Category:
-
File size: 366.9KB
-
File size: 6.0MB
-
File size: 1.1MB
Product Model
Model | Overview | Product Brochure |
| ZX1085BX | Basic Accuracy: ±0.1%; Frequency: 50 Hz–200 kHz, 46 points; Test Level: 10 mV–1 V. | |
| ZX7575BX | Basic Accuracy: ±0.1%; Frequency: 100 Hz, 120 Hz, 1 kHz, 10 kHz; Test Level: 0.1 V, 0.3 V, 1.0 V. | |
| ZX7576BX | Basic Accuracy: ±0.1%; Frequency: 50 Hz–100 kHz, 34 points; Test Level: 0.1 V, 0.3 V, 1.0 V. |
Functions & Advantages
● 0.1% test accuracy, fast measurement speed (40 meas/sec) ● High cost-effectiveness (includes standalone test function, dual-purpose), the best choice for balanced component testing. ● Pass/Fail LED indicators and buzzer alarm | ● Supports USB flash drive upgrades, measurement data can be quickly saved to USB. ● Test condition storage: 50 sets internally, 500 sets on USB flash drive ● Simplified Chinese and English operation languages, easy to use. | ● Key lock function; automatically saves test conditions on power-off ● Easy PC connection for data recording, saving, and processing ● Multiple internal resistance modes available |
Multifunctional Support for Reliable Measurements
◆ Open/Short Zeroing Function
Supports all-frequency and spot-frequency zeroing, with separate correction for AC measurement and DC resistance measurement, effectively eliminating errors introduced by test fixtures and cables.

◆ Averaging Function
Configurable averaging from 1 to 255 readings, effectively filtering random noise and improving measurement consistency.
◆ Trigger Delay Function
Programmable trigger delay ensures measurements are taken after the test signal has stabilized, preventing reading fluctuations caused by insufficient settling time.

Dual-Mode Operation for Versatile Testing
◆ Balance Measurement Mode
In this default mode, a single clamping action automatically completes dual-unit measurement, balance calculation, and PASS/FAIL judgment — eliminating manual recording and arithmetic operations for efficient batch testing on production lines.
◆ Single Measurement Mode
Switching to this mode allows detailed parameter measurement (L, R, Q, |Z|, etc.) for each unit, suitable for R&D parameter validation, material evaluation, and production line failure analysis — expanding the instrument's application depth.
User-Friendly Design for Enhanced Test Experience
◆ Data Logging and Export
Both test data and screen captures can be saved to a USB flash drive with one click for quality traceability and data archiving — no PC connection required.
◆ System Upgrade Without Return to Factory
The instrument supports system software upgrades via USB flash drive, eliminating the need to return the unit to the factory for the latest features and optimizations — reducing maintenance costs and downtime.
◆ File Management Function
The BX series stores up to 50 test setup files internally and 500 on an external USB flash drive. One-click recall during production changeovers reduces repetitive setup time.

◆ Audible and Visual Alarm for Defective Products
Multi-state buzzer function: PASS and FAIL can be independently configured with distinct tones, with clear differences in frequency, pitch, or rhythm for quick identification.
Comparator indicator lights: Red/green LEDs display judgment results, allowing operation without looking at the screen for improved efficiency.
◆ Key Lock Function
Prevents accidental modification of configured parameters, avoiding test anomalies caused by unintended operations.

Automated Production Line Integration
◆ High-Speed Automated Judgment
The BX series delivers up to 40 meas/sec (single parameter, single test) with range lock function, reducing per-unit test time and increasing throughput for batch production line inspection.

◆ Comparator Function
Automatically judges test results against set upper/lower limits, displaying and outputting the judgment results. Output is also available via the HANDLER interface.

◆ HANDLER Sorting Interface
Equipped with RS-232C, USBTMC, USBCDC, USBHID, and optional GPIB. SCPI command set support enables PC/PLC remote control and data acquisition.
◆ Multiple Communication Interfaces
These interfaces enable the formation of automated test systems, outputting binning comparison results and handshake signals while receiving external start signals.
Four-Terminal Kelvin Measurement
Independent source and sense terminals effectively eliminate errors caused by contact resistance and cable impedance, ensuring accuracy and repeatability in low-impedance measurements.

Parameters & Dimensions
| Model | ZX1085BX | ZX7575BX | ZX7576BX | |
| Test Frequency | 50 Hz to 200 kHz, 46 points | 100 Hz, 120 Hz, 1 kHz, 10 kHz | 50 Hz to 100 kHz, 34 points | |
| Test Parameters | L, R, Q, |Z|, DCR, θ | L, R, Q, |Z|, θ | ||
| Test Speed | Fast: 40 meas/sec, Medium: 20 meas/sec, Slow: 6 meas/sec | |||
| Test Level | 10 mV to 1 Vrms | 0.1 Vrms, 0.3 Vrms, 1.0 Vrms | ||
| Signal Source Impedance | 30 Ω, 100 Ω, 10 / 100 Ω, 10 Ω/CC, 50 Ω | 30 Ω, 100 Ω | ||
| Basic Accuracy | 0.1%, refer to the accuracy table | |||
| Range Mode | Auto, Hold | |||
| Trigger Mode | Internal, Manual, Auto, External, Bus | |||
| Correction Function | Open/Short, All-frequency zeroing, Spot-frequency zeroing | |||
| Test Box Balancing Fixture | Test Box Balancing Fixture or custom cable | |||
Display Range | |Z| | 0.1 mΩ to 99.999 MΩ | 0.1 mΩ to 99.999 MΩ | |
| L | 0.0001 μH to 999.99 H | 0.0001 μH to 9999.9 H | ||
| R | 0.01 mΩ to 99.999 MΩ | 0.1 mΩ to 99.999 MΩ | ||
| Q | 0.1–9999.9 | 0.1–9999.9 | ||
| θ(RAD) | -3.14159 to 3.14159 | -3.14159 to 3.14159 | ||
| θ(DEG) | -179.99° to 179.99° | -179.99° to 179.99° | ||
| Δ% | -99.999% to 99.999% | -99.999% to 99.999% | ||
| Equivalent Circuit | Series, Parallel | |||
Comparator | BIN0–BIN3, NG, AUX | |||
| PASS, HI, LOW (PASS/FAIL LED indication) | ||||
Interface | GPIB (optional) | |||
| RS-232C, USB Host, USB Device, Handler | ||||
| Memory | Internal: 50 sets External USB flash drive: 500 sets | |||
| Temperature & Humidity | 0 °C to 40 °C, Relative Humidity ≤ 75% | |||
| Power Requirements | Voltage: 100 to 120 VAC or 198 to 242 VAC | |||
| Frequency: 46 to 64 Hz, Power >50 VA | ||||
| Dimensions (W × H × D) | 310 mm × 110 mm × 315 mm | |||
| Weight (net weight) | 5.5 kg | |||

Unit: millimeters (mm)
Accessories & Options
ZX28Y04 Kelvin Test Cable
ZX75BXY01 Test Box
Software & Resources
Solutions
undefined
Customer Q&A
Q: The instrument is set to auto-trigger mode, but why does it still not trigger when the DUT is placed?
A: The instrument triggers based on impedance detection. If the DUT impedance exceeds the auto-trigger threshold, triggering will not occur. Navigate to [System Interface] → [Test Configuration], locate the "Z≤xxkΩ" setting, and increase the value appropriately.
Q: Why do the values measured by the instrument differ from those measured by other instruments?
A: Pay attention to the instrument's output impedance setting. Different output impedance settings will lead to different measurement results.
Q: The upper and lower limits have been set, but why does the instrument not output PASS or FAIL after measurement?
A: Enter the settings menu and change the "Comparator" function from OFF to ON.