ZX6586 Series Capacitor Leakage Current / Insulation Resistance Tester

The ZX6586 series capacitor leakage current/insulation resistance testers feature a clear and intuitive user interface, offering higher cost-effectiveness while meeting conventional testing requirements. Available in two maximum test voltage specifications—500 V and 800 V—with a fixed charging current of 120 mA. The instrument delivers wide-range leakage current measurement from 0.001 μA to 20.00 mA with a basic accuracy of ±(1% + 0.05 μA). It is suitable for leakage current/insulation resistance testing of electrolytic capacitors and ceramic capacitors, as well as diode reverse characteristic testing. Equipped with comprehensive communication and control interfaces, the series is easy to integrate into automated test systems.
  • File size: 372.3KB

  • File size: 4.9MB

  • File size: 1.2MB


Product Model

Model

Overview

Product Brochure

ZX6586-500 V Test Voltage: 1 V–500 V, continuously adjustable; LC/IR testing.

Click to View

ZX6586-800 VTest Voltage: 1 V–800 V, continuously adjustable; LC/IR testing.

Click to View

Functions & Advantages

● High reliability, high stability, color LCD display

● Measurement range: 0.001 μA–20.00 mA, 4-digit display

● SCPI commands for easy integration into automated systems

● Test conditions automatically saved: 50 sets internally, 500 sets on USB flash drive

● Flexible interface functions for customizable data recording, saving, and processing

● Multiple interfaces: RS-232C, USB Device, Handler, GPIB (optional)

● Comparator function for pass/fail sorting

● Automatic USB flash drive upgrades for convenient customization

 

Capacitor Leakage Current Measurement Principle

◆  Three Components of Total Leakage Current

In actual measurement, the measured leakage current value depends on the time point at which measurement is taken after the test voltage is applied. Understanding this is essential for proper instrument operation.

The total leakage current of a capacitor consists of the following three components:

01. Insulation resistance current (Curve ①) — Current flowing through the insulation resistance IR, dependent on the test voltage, with a flat time response.

02. Charging current (Curve ②) — Current charging capacitor C when the test voltage is applied. This is a transient component that decays rapidly to zero.

03. Dielectric absorption current (Curve ③) — Generated by the Rd and Cd equivalent network, decaying exponentially at a rate dependent on the dielectric material characteristics.

The total leakage current response is the superposition of the above three components, ultimately converging to the current flowing through the insulation resistance. Therefore, leakage current measurement must be performed after the charging current and dielectric absorption current have sufficiently decayed to obtain a stable, true leakage current value.

 

Product Core Advantages

◆  Fixed Charging Current — Hassle-Free and Cost-Effective Choice

The instrument features a fixed charging current of 120 mA, suitable for the charging requirements of most electrolytic and ceramic capacitors. This eliminates the need for current setting, lowering the operational barrier, while effectively controlling overall instrument cost without compromising measurement reliability — delivering excellent cost-performance.

◆  Wide Range Coverage for Precise μA-Level Leakage Current Measurement

This series features a built-in high-voltage DC power supply with an output voltage range of 1.0 V to 500 V/800 V (model-dependent), covering various leakage current and insulation resistance testing scenarios from low-voltage ceramic capacitors to high-voltage electrolytic capacitors. The leakage current measurement range covers 0.001 μA to 20.00 mA with a basic accuracy of ±(1% + 0.05 μA), delivering stable and reliable measurements for quality control and failure prediction.

◆  Real-Time Output Voltage Monitoring for Operational Safety

To ensure operational safety, the series continuously monitors the actual output voltage during both testing and setup states, displaying the monitored voltage value Vm on the test page.

◆  Multi-Stage Constant Power Discharge for Fast Discharging of Large Capacitors

For fast and safe discharge after testing, the series features a built-in 50 W multi-stage constant power discharge circuit, meeting the rapid discharge requirements of large-capacitance capacitors.

◆  Comprehensive Interfaces for Easy Automated System Integration

The series is equipped with standard RS-232, USB Device (supporting USBCDC/USBTMC/USB HID), and Handler interfaces, enabling remote control and test data acquisition for R&D or quality inspection applications. GPIB is available as an optional feature for automation needs.

 

Adaptable to Different Test Scenarios

◆  Measurement Modes

Test (Auto): A single trigger automatically completes the full test sequence of charging, measurement, and discharge.

Test (Single Step): Single-step manual testing with external trigger setting is required for integration with automated equipment.

 

Precise Timing Control

◆  Timing Mode

Select the timing start point for charging to accommodate different test standards:

Vm = Vs Mode: Charging time starts when the monitored voltage reaches the set test voltage, in accordance with JIS standards.

Vm = 0 Mode: Charging time starts immediately when charging begins, i.e., when the monitored voltage is 0 V.

◆  Charging Time

Sets the charging duration (adjustable from 0 to 999 s), with the specific meaning depending on the selected timing mode. The charging time must be sufficient for the leakage current to fully stabilize; insufficient time will result in higher readings. It is recommended to start with a longer charging time, observe when the reading stabilizes, and then gradually shorten it to balance efficiency and accuracy.

◆  Test Delay

Sets a stabilization wait time between the completion of charging and the start of measurement (adjustable from 0.2 to 999.0 s) to ensure the current has further stabilized before measurement.

◆  Trigger Delay

Sets a delay between the external trigger signal and the start of measurement, facilitating timing matching with automated equipment for stable and reliable results.

 

Component Test Applications

◆  Aluminum Electrolytic Capacitor Leakage Current Testing

◆  Solid Capacitor Leakage Current Testing

◆  Film Capacitor Insulation Resistance Testing

◆  Diode Reverse Characteristic Testing

Parameters & Dimensions

ModelZX6586_500ZX6586_800
Test Voltage1–500 V, Continuously Adjustable1–800 V, Continuously Adjustable
Test ParameterLC (leakage current), IR (insulation resistance)
Voltage Accuracy0.5% setting ± 0.2 V
Measurement RangeLC (0.001 μA–20.00 mA), IR (0.01 kΩ–99.99 GΩ)
Measurement Accuracy1% ± 0.05 μA
Charging Time0–999 s, Continuously Adjustable
Test TimeFast: Approx. 30 meas/sec, Medium: Approx. 15 meas/sec, Slow: Approx. 6 meas/sec
Test RangeAuto, 20 mA, 2 mA, 200 µA, 20 µA, 2 µA (Total 5 Ranges)
HANDLER InterfacePass, Fail, HI, LOW, Buzzer Alarm, LED Display
Rich InterfacesRS-232C, USB DEVICE, GPIB (optional), HANDLER Interface
Dimensions (W × H × D)310 mm × 110 mm × 315 mm
Weight8 kg

Unit: millimeters (mm)

Accessories & Options

ZX65Y01B Leakage Current Test Cable

ZX65Y01B Leakage Current Test Cable

ZX65Y01R Leakage Current Test Cable

ZX65Y01R Leakage Current Test Cable

ZX65Y01M Leakage Current Test Cable

ZX65Y01M Leakage Current Test Cable

ZX65Y03 Leakage Current Test Short Fixture

ZX65Y03 Leakage Current Test Short Fixture

ZX65Y15-20 mm / 15 mm Leakage Current Test Long Fixture

ZX65Y15-20 mm / 15 mm Leakage Current Test Long Fixture

Software & Resources

Solutions

undefined

undefined

Customer Q&A

Enter information to retrieve data.

By systematically retrieving and analyzing relevant input information, comprehensive and specialized data are obtained to support or meet specific needs or objectives.

Confirm
%{tishi_zhanwei}%