Product Categories
ZX6589/ZX6592 Series Capacitor Leakage Current/Insulation Resistance Tester
-
File size: 400.1KB
-
File size: 5.6MB
-
File size: 1.3MB
Product Model
Model | Overview | Product Brochure |
| ZX6589-500 V | Test Voltage: 1–500 V; Measurement Range LC: 0.001 μA–20.00 mA, IR: 0.01 kΩ–99.99 GΩ; Max Charging Current: 500 mA. | |
| ZX6589-800 V | Test Voltage: 1–800 V; Measurement Range LC: 0.001 μA–20.00 mA, IR: 0.01 kΩ–99.99 GΩ; Max Charging Current: 500 mA. | |
| ZX6592-500 V | Test Voltage: 1–500 V; Upgraded version of ZX6589 with improved constant current and LC detection sections. | Click to View |
| ZX6592-800 V | Test Voltage: 1–800 V; Upgraded version of ZX6589 with improved constant current and LC detection sections. |
Functions & Advantages
● High-precision constant current charging function (3%+0.5 mA) ● High current (500 mA) for faster charging of low-voltage, high-capacitance capacitors ● Measurement range: 0.001 μA – 20.00 mA, 4-digit display | ● Test conditions automatically saved: 50 sets internally, 500 sets on USB flash drive ● Simplified Chinese and English operation languages with selectable display styles ● Flexible interface functions for customizable data recording, saving, and processing | ● Rear panel BNC trigger for quick connection to an external foot switch ● Comparator function for pass/fail sorting ● Automatic USB flash drive upgrades for convenient customization ● Upload results to PC without software installation |
Capacitor Leakage Current Measurement Principle
◆ Three Components of Total Leakage Current
In actual measurement, the measured leakage current value depends on the time point at which measurement is taken after the test voltage is applied. Understanding this is essential for proper instrument operation.

The total leakage current of a capacitor consists of the following three components:
01. Insulation resistance current (Curve ①) — Current flowing through the insulation resistance IR, dependent on the test voltage, with a flat time response.
02. Charging current (Curve ②) — Current charging capacitor C when the test voltage is applied. This is a transient component that decays rapidly to zero.
03. Dielectric absorption current (Curve ③) — Generated by the Rd and Cd equivalent network, decaying exponentially at a rate dependent on the dielectric material characteristics.
The total leakage current response is the superposition of the above three components, ultimately converging to the current flowing through the insulation resistance. Therefore, leakage current measurement must be performed after the charging current and dielectric absorption current have sufficiently decayed to obtain a stable, true leakage current value.
Product Core Advantages
◆ Wide-Range High-Voltage Output with Fast Charging for Large Capacitors
This series features a built-in high-voltage DC power supply with an output voltage range of 1.0 V to 500 V/800 V (model-dependent), covering applications from low-voltage capacitor leakage current testing to aluminum foil withstanding voltage testing. The charging current is adjustable from 0.5 mA to 500 mA (limited by the 50 W maximum output power when voltage > 100 V), enabling rapid charging of large-capacitance products.

◆ High-Precision Constant Current Charging for Aluminum Foil Withstanding Voltage Testing
The oxide film of positive aluminum foil in aluminum electrolytic capacitors is typically tested with a very low constant current for film withstanding voltage and voltage rise time. Depending on the foil type, the test current is generally 0.5 mA, 1 mA, or 2 mA (±10%). This series achieves charging current accuracy of ±(3%+0.05 mA), providing stable constant current output as low as 0.5 mA.
◆ Wide Range Coverage for Precise μA-Level Leakage Current Measurement
Leakage current measurement range covers 0.001 μA to 20.00 mA, meeting the leakage current and insulation resistance testing requirements for various capacitors including electrolytic capacitors and high-k ceramic capacitors. The ZX6592 series delivers stable readings without rebound in μA-level measurements.
◆ Real-Time Output Voltage Monitoring for Operational Safety
To ensure operational safety, the series continuously monitors the actual output voltage during both testing and setup states, displaying the monitored voltage value Vm on the test page.
◆ Multi-Stage Constant Power Discharge for Fast Discharging of Large Capacitors
For fast and safe discharge after testing, the series features a built-in 50 W multi-stage constant power discharge circuit, meeting the rapid discharge requirements of large-capacitance capacitors.
◆ Comprehensive Interfaces for Easy Automated System Integration
The series is equipped with standard RS-232, USB Device (supporting USBCDC/USBTMC/USB HID), and Handler interfaces, enabling remote control and test data acquisition for R&D or quality inspection applications. GPIB is available as an optional feature for automation needs.
Adaptable to Different Test Scenarios
◆ Measurement Modes
Sequential Auto Test: A single trigger automatically completes the full test sequence of charging, measurement, and discharge.
Single-Step Manual Test: Single-step manual testing with external trigger setting is required for integration with automated equipment.
Continuous Auto Test: After triggering, charging begins with continuous measurement and no discharge, suitable for observing the full leakage current variation trend with data acquisition.
Aluminum Foil Withstanding Voltage Test (optional): For testing aluminum foil withstanding voltage (Vt) and rise time (Tr).
Precise Timing Control
◆ Timing Mode
Select the timing start point for charging to accommodate different test standards:
Vm = Vs Mode: Charging time starts when the monitored voltage reaches the set test voltage, in accordance with JIS standards.
Vm = 0 Mode: Charging time starts immediately when charging begins, i.e., when the monitored voltage is 0 V.

◆ Charging Time
Sets the charging duration (adjustable from 0 to 999 s), with the specific meaning depending on the selected timing mode. The charging time must be sufficient for the leakage current to fully stabilize; insufficient time will result in higher readings. It is recommended to start with a longer charging time, observe when the reading stabilizes, and then gradually shorten it to balance efficiency and accuracy.
◆ Test Delay
Sets a stabilization wait time between the completion of charging and the start of measurement (adjustable from 0.2 to 999.0 s) to ensure the current has further stabilized before measurement.
◆ Trigger Delay
Sets a delay between the external trigger signal and the start of measurement, facilitating timing matching with automated equipment for stable and reliable results.
Component Test Applications
◆ Aluminum Electrolytic Capacitor Leakage Current Testing

◆ Solid Capacitor Leakage Current Testing

◆ Film Capacitor Insulation Resistance Testing

◆ Diode Reverse Characteristic Testing

Parameters & Dimensions
| Model | ZX6589 | ZX6592 |
| Test Voltage | ZX6589_500 V: Test Voltage 1–500 V ZX6589_800 V: Test Voltage 1–800 V | ZX6592_500 V: Test Voltage 1–500 V ZX6592_800 V: Test Voltage 1–800 V |
| Test Function | LC (leakage current), IR (insulation resistance) Charge, Test, Discharge | LC (Leakage Current) Charge, Test, Discharge |
| Voltage Accuracy | (0.5% of the setting ± 0.2 V) | |
| Charging Current | LEV ≤ 100 V: 0.5 mA–500 mA; > 100 V: 0.5 mA–IMAX, (3% ± 0.05 mA), where IMAX = 50 W / Test Voltage | |
| Measurement Range | LC (0.001 μA to 20.00 mA) IR (0.01 kΩ to 99.99 GΩ) | LC (0.001 μA to 20.00 mA) |
| Basic Accuracy | LC: (0.3% ± 0.05 μA) | |
| Charging Time | 0–999 s, Manually Adjustable | |
| Test Time | Fast: 33 ms, Medium: 67 ms, Slow: 166 ms (Measurement conditions: range locked, trigger mode set to EXT, and external trigger voltage immediately disabled) | |
| Measurement Range | Hold, Auto: 2 μA, 20 μA, 200 μA, 2 mA, 20 mA | |
| HANDLER Interface | Pass, Fail, HI, LOW, PASS/FAIL Alarm Settings | |
| Rich Interfaces | RS-232C, USB, GPIB (optional) | |
| Dimensions (W × H × D) | 310 mm × 110 mm × 315 mm | |
| Weight | 8 kg | |

Unit: millimeters (mm)
Accessories & Options
ZX65Y01B Leakage Current Test Cable
ZX65Y01R Leakage Current Test Cable
ZX65Y01M Leakage Current Test Cable
ZX65Y03 Leakage Current Test Short Fixture
ZX65Y15-20 mm / 15 mm Leakage Current Test Long Fixture
Software & Resources
Solutions
undefined
Customer Q&A
Q: Under low-current conditions, auto range has been set, but the measured data is still too high. How can this be improved?
A: A small current exists in the loop. Perform open-circuit zeroing (zeroing test) during no-load measurement to clear the current offset, which will improve the result.
Q: When testing a product, why does the instrument start testing before the set voltage is reached?
A: This is generally caused by the charging current being set too low. Either extend the charging time or increase the charging current.
Q: What may cause the measured current value to be abnormally high or low?
A: The range does not match the actual current range. Select auto range.
Q: When no current value is displayed during testing and only a horizontal bar appears, how should this be handled?
A: The current is over range. Select auto range; note, however, that currents above 2 mA require manual selection of the 20 mA range.