ZX6589/ZX6592 Series Capacitor Leakage Current/Insulation Resistance Tester

The ZX6589/ZX6592 series capacitor leakage current/insulation resistance testers offer maximum test voltages of 500 V and 800 V, with charging current adjustable from 0.5 mA to 500 mA (limited to 50 W output power when voltage > 100 V). They support leakage current and insulation resistance testing for electrolytic and ceramic capacitors, as well as anode foil withstanding voltage testing for aluminum electrolytic capacitors. Additionally, they can verify operating voltage and measure leakage current for surge absorbers, Zener diodes, and neon lamps. With comprehensive communication and control interfaces, these testers are ideal for integration into automated test systems. The ZX6592 series, in particular, is optimized for μA-level leakage current measurement, delivering high stability, reliability, and bounce-free readings.
  • File size: 400.1KB

  • File size: 5.6MB

  • File size: 1.3MB


Product Model

Model

Overview

Product Brochure

ZX6589-500 VTest Voltage: 1–500 V; Measurement Range LC: 0.001 μA–20.00 mA, IR: 0.01 kΩ–99.99 GΩ; Max Charging Current: 500 mA.

Click to View

ZX6589-800 VTest Voltage: 1–800 V; Measurement Range LC: 0.001 μA–20.00 mA, IR: 0.01 kΩ–99.99 GΩ; Max Charging Current: 500 mA.

Click to View

ZX6592-500 VTest Voltage: 1–500 V; Upgraded version of ZX6589 with improved constant current and LC detection sections.Click to View
ZX6592-800 VTest Voltage: 1–800 V; Upgraded version of ZX6589 with improved constant current and LC detection sections.

Click to View

Functions & Advantages

● High-precision constant current charging function (3%+0.5 mA)

● High current (500 mA) for faster charging of low-voltage, high-capacitance capacitors

● Measurement range: 0.001 μA – 20.00 mA, 4-digit display

● Test conditions automatically saved: 50 sets internally, 500 sets on USB flash drive

● Simplified Chinese and English operation languages with selectable display styles

● Flexible interface functions for customizable data recording, saving, and processing

● Rear panel BNC trigger for quick connection to an external foot switch

● Comparator function for pass/fail sorting

● Automatic USB flash drive upgrades for convenient customization

● Upload results to PC without software installation

 

Capacitor Leakage Current Measurement Principle

◆  Three Components of Total Leakage Current

In actual measurement, the measured leakage current value depends on the time point at which measurement is taken after the test voltage is applied. Understanding this is essential for proper instrument operation.

The total leakage current of a capacitor consists of the following three components:

01. Insulation resistance current (Curve ①) — Current flowing through the insulation resistance IR, dependent on the test voltage, with a flat time response.

02. Charging current (Curve ②) — Current charging capacitor C when the test voltage is applied. This is a transient component that decays rapidly to zero.

03. Dielectric absorption current (Curve ③) — Generated by the Rd and Cd equivalent network, decaying exponentially at a rate dependent on the dielectric material characteristics.

The total leakage current response is the superposition of the above three components, ultimately converging to the current flowing through the insulation resistance. Therefore, leakage current measurement must be performed after the charging current and dielectric absorption current have sufficiently decayed to obtain a stable, true leakage current value.

 

Product Core Advantages

◆  Wide-Range High-Voltage Output with Fast Charging for Large Capacitors

This series features a built-in high-voltage DC power supply with an output voltage range of 1.0 V to 500 V/800 V (model-dependent), covering applications from low-voltage capacitor leakage current testing to aluminum foil withstanding voltage testing. The charging current is adjustable from 0.5 mA to 500 mA (limited by the 50 W maximum output power when voltage > 100 V), enabling rapid charging of large-capacitance products.

◆  High-Precision Constant Current Charging for Aluminum Foil Withstanding Voltage Testing

The oxide film of positive aluminum foil in aluminum electrolytic capacitors is typically tested with a very low constant current for film withstanding voltage and voltage rise time. Depending on the foil type, the test current is generally 0.5 mA, 1 mA, or 2 mA (±10%). This series achieves charging current accuracy of ±(3%+0.05 mA), providing stable constant current output as low as 0.5 mA.

◆  Wide Range Coverage for Precise μA-Level Leakage Current Measurement

Leakage current measurement range covers 0.001 μA to 20.00 mA, meeting the leakage current and insulation resistance testing requirements for various capacitors including electrolytic capacitors and high-k ceramic capacitors. The ZX6592 series delivers stable readings without rebound in μA-level measurements.

◆  Real-Time Output Voltage Monitoring for Operational Safety

To ensure operational safety, the series continuously monitors the actual output voltage during both testing and setup states, displaying the monitored voltage value Vm on the test page.

◆  Multi-Stage Constant Power Discharge for Fast Discharging of Large Capacitors

For fast and safe discharge after testing, the series features a built-in 50 W multi-stage constant power discharge circuit, meeting the rapid discharge requirements of large-capacitance capacitors.

◆  Comprehensive Interfaces for Easy Automated System Integration

The series is equipped with standard RS-232, USB Device (supporting USBCDC/USBTMC/USB HID), and Handler interfaces, enabling remote control and test data acquisition for R&D or quality inspection applications. GPIB is available as an optional feature for automation needs.

 

Adaptable to Different Test Scenarios

◆  Measurement Modes

Sequential Auto Test: A single trigger automatically completes the full test sequence of charging, measurement, and discharge.

Single-Step Manual Test: Single-step manual testing with external trigger setting is required for integration with automated equipment.

Continuous Auto Test: After triggering, charging begins with continuous measurement and no discharge, suitable for observing the full leakage current variation trend with data acquisition.

Aluminum Foil Withstanding Voltage Test (optional): For testing aluminum foil withstanding voltage (Vt) and rise time (Tr).

 

Precise Timing Control

◆  Timing Mode

Select the timing start point for charging to accommodate different test standards:

Vm = Vs Mode: Charging time starts when the monitored voltage reaches the set test voltage, in accordance with JIS standards.

Vm = 0 Mode: Charging time starts immediately when charging begins, i.e., when the monitored voltage is 0 V.

◆  Charging Time

Sets the charging duration (adjustable from 0 to 999 s), with the specific meaning depending on the selected timing mode. The charging time must be sufficient for the leakage current to fully stabilize; insufficient time will result in higher readings. It is recommended to start with a longer charging time, observe when the reading stabilizes, and then gradually shorten it to balance efficiency and accuracy.

◆  Test Delay

Sets a stabilization wait time between the completion of charging and the start of measurement (adjustable from 0.2 to 999.0 s) to ensure the current has further stabilized before measurement.

◆  Trigger Delay

Sets a delay between the external trigger signal and the start of measurement, facilitating timing matching with automated equipment for stable and reliable results.

 

Component Test Applications

◆  Aluminum Electrolytic Capacitor Leakage Current Testing

◆  Solid Capacitor Leakage Current Testing

◆  Film Capacitor Insulation Resistance Testing

◆  Diode Reverse Characteristic Testing

Parameters & Dimensions

ModelZX6589ZX6592
Test Voltage

ZX6589_500 V: Test Voltage 1–500 V

ZX6589_800 V: Test Voltage 1–800 V

ZX6592_500 V: Test Voltage 1–500 V

ZX6592_800 V: Test Voltage 1–800 V

Test Function

LC (leakage current), IR (insulation resistance)

Charge, Test, Discharge

LC (Leakage Current)

Charge, Test, Discharge

Voltage Accuracy(0.5% of the setting ± 0.2 V)
Charging CurrentLEV ≤ 100 V: 0.5 mA–500 mA; > 100 V: 0.5 mA–IMAX, (3% ± 0.05 mA), where IMAX = 50 W / Test Voltage
Measurement Range

LC (0.001 μA to 20.00 mA)

IR (0.01 kΩ to 99.99 GΩ)

LC (0.001 μA to 20.00 mA)
Basic AccuracyLC: (0.3% ± 0.05 μA)
Charging Time0–999 s, Manually Adjustable
Test TimeFast: 33 ms, Medium: 67 ms, Slow: 166 ms (Measurement conditions: range locked, trigger mode set to EXT, and external trigger voltage immediately disabled)
Measurement RangeHold, Auto: 2 μA, 20 μA, 200 μA, 2 mA, 20 mA
HANDLER InterfacePass, Fail, HI, LOW, PASS/FAIL Alarm Settings
Rich InterfacesRS-232C, USB, GPIB (optional)
Dimensions (W × H × D)310 mm × 110 mm × 315 mm
Weight8 kg

Unit: millimeters (mm)

Accessories & Options

ZX65Y01B Leakage Current Test Cable

ZX65Y01B Leakage Current Test Cable

ZX65Y01R Leakage Current Test Cable

ZX65Y01R Leakage Current Test Cable

ZX65Y01M Leakage Current Test Cable

ZX65Y01M Leakage Current Test Cable

ZX65Y03 Leakage Current Test Short Fixture

ZX65Y03 Leakage Current Test Short Fixture

ZX65Y15-20 mm / 15 mm Leakage Current Test Long Fixture

ZX65Y15-20 mm / 15 mm Leakage Current Test Long Fixture

Software & Resources

Solutions

undefined

undefined

Customer Q&A

Q: Under low-current conditions, auto range has been set, but the measured data is still too high. How can this be improved?

A: A small current exists in the loop. Perform open-circuit zeroing (zeroing test) during no-load measurement to clear the current offset, which will improve the result.

Q: When testing a product, why does the instrument start testing before the set voltage is reached?

A: This is generally caused by the charging current being set too low. Either extend the charging time or increase the charging current.

Q: What may cause the measured current value to be abnormally high or low?

A: The range does not match the actual current range. Select auto range.

Q: When no current value is displayed during testing and only a horizontal bar appears, how should this be handled?

A: The current is over range. Select auto range; note, however, that currents above 2 mA require manual selection of the 20 mA range.