Product Categories
ZX8536 High-Speed Precision LCR Meter
Category:
-
File size: 6.3MB
-
File size: 300.8KB
-
File size: 5.3MB
Product Model
| Model | Overview | Product Brochure |
| ZX8536 | 4 Hz – 8 MHz Precision LCR Meter; 1 ms High-Speed Measurement; Basic Accuracy: ±0.05%. | Click to View |
Functions & Advantages
● High precision: basic accuracy 0.05% ● High speed: ADC time as fast as 1 ms ● Wide frequency: 4 Hz to 8 MHz measurement frequency range ● Contact check function | ● Simplified Chinese and English operation languages ● Graphical sweep, open/short/load correction, and other functions ● Save test data and test conditions (via USB flash drive or internal memory) ● Direct screen capture of graphical sweep images to USB flash drive | ● Enhanced test terminal protection function ● Host computer interfaces: USB, GPIB (optional), RS-232C, LAN (optional) ● Handler interface: optional DB37 or CN36 connector |
High Speed, High Precision, and Maintains High Speed at Low Frequencies (e.g., 120 Hz and Below)
◆ High Speed & High Precision
±0.05% rdg. high precision — deviation is only 1/8 of previous models, with measurement speed up to 5 times faster than conventional instruments, boosting production capacity.

◆ High Speed at Low Frequencies
Thanks to the innovative use of high-speed sampling technology, this instrument maintains high-speed measurement even at low frequencies (e.g., 120 Hz and below), with ADC conversion time at low frequencies reduced to one-fifth of that of conventional instruments.

Fast and Accurate Dielectric Constant Analysis
◆ Automatic Calculation of Conductivity and Dielectric Constant
Simply enter the calculation parameters (length and cross-sectional area), and the instrument will automatically generate the results — no manual calculations required! We highly recommend pairing with the Zhixin Precision dedicated dielectric constant test fixture ZX85Y77(L) for fast and precise measurements!

◆ Dedicated Dielectric Constant Test Fixture
The ZX85Y77(L) is equipped with four interchangeable test electrodes, supporting multiple testing methods for various solid materials. It also features a specifically designed guard electrode to eliminate measurement errors caused by fringing capacitance, significantly enhancing measurement accuracy and ensuring precise determination of dielectric constant.

7-Inch Large LCD Screen for Direct Trace Display
◆ Trace Sweep Function
The ZX8536 series features a large 7-inch LCD screen, enabling direct display of measurement sweep traces without the need for an external computer. It also allows flexible configuration of multiple test conditions, facilitating convenient, fast, and intuitive location of typical values. This reduces space requirements, simplifies production line setup, and significantly improves component inspection efficiency on automated production lines.

Parameters & Dimensions
| Model | ZX8536 | |
| Test Frequency | 4 Hz to 8 MHz | |
| Test Parameters | Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tan δ), σ, ε | |
| Measurement Range | 100 mΩ to 100 MΩ, 10 ranges (All parameters are specified by Z) | |
| Display Range | Z: 0.00 m to 9.99999 GΩ, Y: 0.000n to 9.99999 GS, θ: ± (0.000° to 999.999°), Q: ± (0.00 to 9999.99), Rdc: ± (0.00 m to 9.99999 GΩ), D: ± (0.00000 to 9.99999), Δ%: ± (0.000% to 999.999%), etc. | |
| Basic Accuracy | Z: 0.05% rdg. θ: 0.03° (Typical value; Accuracy guaranteed over the range: 1 mΩ to 200 MΩ) | |
| Test Speed | FAST / MED / SLOW / SLOW2; Refer to the table below for corresponding times | |
| Test Signal Level | [V Mode, CV Mode][Normal Mode] | 4 Hz to 1.0000 MHz: 10 mV to 5 V (Max. 50 mA) 1.0001 MHz to 8 MHz: 10 mV to 1 V (Max. 10 mA) |
| [V-mode, CV-mode][Low-Z High-Precision Mode] | 4 Hz to 1.0000 MHz: 10 mV to 1 V (Max. 100 mA) | |
| [CC Mode][Normal Mode] | 4 Hz to 1.0000 MHz: 10 μA to 50 mA (Max. 5 V) 1.0001 MHz to 8 MHz: 10 μA to 10 mA (Max. 1 V) | |
| [CC Mode][Low-Z High-Precision Mode] | 4 Hz to 1.0000 MHz: 10 μA to 100 mA(Max. 1 V) [DC Resistance Measurement]: 1 V fixed | |
| DC Bias Voltage | Measurement Range: DC voltage 0–5 V (0–1 V in low-Z, high-accuracy mode) | |
| Output Impedance | Normal mode: 100 Ω, Low-Z high-precision mode: 10 Ω | |
| Display | Color TFT 7-inch LCD screen | |
| Functions | Comparator, BIN measurement (2 items with 10 bins), trigger function, open-circuit and short-circuit correction, contact check, panel save/recall function, and storage function | |
| Comparator | 10-bin sorting, BIN0–BIN9, NG, AUX | |
| PASS, HI, LOW (PASS/FAIL LED indication) | ||
| Interface | RS-232C, USB Host, USB Device, Handler, GPIB (optional) | |
| Interface | EXT I/O (processor), /USB/USB flash drive/LAN/GP-IB/RS-232C | |
| Power Supply | AC 100 to 240 V, 50/60 Hz, 50 VA max | |
| Dimensions (W × H × D) | 400 mm × 132 mm × 305 mm | |
| Weight | 6 kg | |
◆ Appendix: Analog Measurement Time [ms] (Tf = 1 / Test Frequency)
Test Speed Test Frequency | FAST | MED | SLOW | SLOW2 |
| DC(50 Hz Power Frequency) | 1 ms | 20 ms | 100 ms | 400 ms |
| 4.00 Hz to 10.00 Hz | Tf | 2×Tf | 3×Tf | 4×Tf |
| 10.01 Hz to 39.99 Hz | Tf | 2×Tf | 5×Tf | 10×Tf |
| 40.00 Hz to 99.99 Hz | Tf | 2×Tf | 5×Tf | 40×Tf |
| 100.00 Hz to 300.00 Hz | Tf | 2×Tf | 5×Tf | 50×Tf |
| 300.01 Hz to 500.00 Hz | Tf | 2×Tf | 10×Tf | 200×Tf |
| 500.01 Hz to 1.0000 kHz | Tf | 5×Tf | 20×Tf | 300×Tf |
| 1.0001 kHz to 2.0000 kHz | Tf | 8×Tf | 40×Tf | 600×Tf |
| 2.0001 kHz to 3.0000 kHz | 2×Tf | 12×Tf | 60×Tf | 1200×Tf |
| 3.0001 kHz to 5.0000 kHz | 3×Tf | 20×Tf | 100×Tf | 2000×Tf |
| 5.0001 kHz to 10.000 kHz | 5×Tf | 40×Tf | 200×Tf | 3000×Tf |
| 10.001 kHz to 20.000 kHz | 10×Tf | 80×Tf | 400×Tf | 6000×Tf |
| 20.001 kHz to 30.000 kHz | 25×Tf | 150×Tf | 600×Tf | 12000×Tf |
| 30.001 kHz to 50.000 kHz | 25×Tf | 250×Tf | 1000×Tf | 20000×Tf |
| 50.001 kHz to 100.00 kHz | 50×Tf | 400×Tf | 2000×Tf | 30000×Tf |
| 100.01 kHz to 140.00 kHz | 100×Tf | 800×Tf | 4000×Tf | 60000×Tf |
| 140.01 kHz to 200.00 kHz | 100×Tf | 800×Tf | 4000×Tf | 60000×Tf |
| 200.01 kHz to 300.00 kHz | 250×Tf | 1500×Tf | 6000×Tf | 120000×Tf |
| 300.01 kHz to 400.00 kHz | 250×Tf | 2500×Tf | 10000×Tf | 200000×Tf |
| 400.01 kHz to 500.00 kHz | 250×Tf | 2500×Tf | 10000×Tf | 200000×Tf |
| 500.01 kHz to 700.00 kHz | 500×Tf | 4000×Tf | 20000×Tf | 300000×Tf |
| 700.01 kHz to 1.0000 MHz | 500×Tf | 4000×Tf | 20000×Tf | 300000×Tf |
| 1.0001 MHz to 1.4000 MHz | 1250×Tf | 8750×Tf | 40000×Tf | 600000×Tf |
| 1.4001 MHz to 2.0000 MHz | 1250×Tf | 8750×Tf | 40000×Tf | 600000×Tf |
| 2.0001 MHz to 3.0000 MHz | 1875×Tf | 15000×Tf | 60000×Tf | 900000×Tf |
| 3.0001 MHz to 4.0000 MHz | 2500×Tf | 25000×Tf | 100000×Tf | 1500000×Tf |
| 4.0001 MHz to 5.0000 MHz | 2500×Tf | 25000×Tf | 100000×Tf | 1500000×Tf |
| 5.0001 MHz to 6.0000 MHz | 5000×Tf | 40000×Tf | 156250×Tf | 2500000×Tf |
| 6.0001 MHz to 8.0000 MHz | 5000×Tf | 40000×Tf | 156250×Tf | 2500000×Tf |

Unit: millimeters (mm)
Accessories & Options
ZX85Y47 Kelvin Test Fixture
ZX28Y11AS Four-Terminal Pair (4TP) Test Cable
ZX28Y09 SMD Kelvin Test Cable
ZX28Y08 SMD Test Fixture
ZX85Y77 Dielectric Constant Test Fixture
ZX85Y77L Dielectric Constant Test Fixture
Software & Resources
Solutions
undefined
Customer Q&A
Q: When measuring on the single measurement page, the secondary parameter on the second line is clearly outside the upper/lower limits, yet the instrument still displays PASS. Why?
A: If the secondary parameter needs to be included in the judgment, you must enable the "Auxiliary" option in the binning settings.
Q: In the graphical sweep function, the resonant frequency and impedance readings are incorrect. What should I do?
A: The graphical sweep typically requires an all-frequency zeroing. When using test leads, ensure that the lead position during short zeroing is exactly the same as during measurement, to avoid deviations caused by lead movement.
Q: In the graphical sweep function, only one curve is displayed, making it difficult to observe. How can this be resolved?
A: In the graphical sweep settings, change the display mode to "A+B" and set the Y-axis scale to "LOG".
Q: Why does the instrument not alarm on defective products, or why does it keep beeping constantly?
A: ▪ Make sure the upper/lower limits and nominal value are configured, and that the comparator is turned ON.
▪ Check the beep settings under "System". Set "Pass Beep" and "Fail Beep" to the desired mode.
Q: Why do the readings fluctuate significantly and become unstable during zeroing?
A: When shorting the clips, ensure that the corresponding color-matched clips (red-to-blue and black-to-white) are clipped on the same side.
Q: When connecting to a PLC, the instrument output signal is found to be invalid. How can this be resolved?
A: The Handler interface output mode is set to "Hold" by default. You can change it to "Delay Clear" or "Start Clear" mode.
Q: Why do the measured values differ significantly from the standard values?
A: ▪ Check whether the short-circuit reading (pay attention to the clip connection method) is near 0 mΩ. Re-zero the instrument whenever the test environment changes, such as after replacing the fixture or test leads.
▪ Check whether compensation has been applied. Try disabling compensation and re-zeroing.
▪ If the test leads are long, have multiple adapters, or are aged, inspect all four test leads for open circuits or poor contact.
▪ Verify that the instrument's range matches the DUT. A large range mismatch can cause measurement errors.