Product Categories
ZX8590 30 MHz Impedance Analyzer
Category:
-
File size: 6.4MB
-
File size: 986.2KB
-
File size: 4.2MB
Product Model
| Model | Overview | Product Brochure |
| ZX8590-5M | High-precision broadband LCR meter with impedance analysis function; Continuous frequency from 20 Hz to 5 MHz; Basic Accuracy: ±0.05%; Four-terminal pair auto-balancing measurement technology. | Click to View |
| ZX8590-10M | High-precision broadband LCR meter with impedance analysis function; Continuous frequency from 20 Hz to 10 MHz; Basic Accuracy: ±0.05%; Four-terminal pair auto-balancing measurement technology. | Click to View |
| ZX8590-15M | High-precision broadband LCR meter with impedance analysis function; Continuous frequency from 20 Hz to 15 MHz; Basic Accuracy: ±0.05%; Four-terminal pair auto-balancing measurement technology. | Click to View |
| ZX8590-20M | High-precision broadband LCR meter with impedance analysis function; Continuous frequency from 20 Hz to 20 MHz; Basic Accuracy: ±0.05%; Four-terminal pair auto-balancing measurement technology. | Click to View |
| ZX8590-25M | High-precision broadband LCR meter with impedance analysis function; Continuous frequency from 20 Hz to 25 MHz; Basic Accuracy: ±0.05%; Four-terminal pair auto-balancing measurement technology. | Click to View |
| ZX8590-30M | High-precision broadband LCR meter with impedance analysis function; Continuous frequency from 20 Hz to 30 MHz; Basic Accuracy: ±0.05%; Four-terminal pair auto-balancing measurement technology. | Click to View |
Functions & Advantages
● Auto-balancing bridge technology, four-terminal pair Kelvin test terminals ● Optional internal ±40 V bias voltage source ● Simplified Chinese and English operation languages ● Bin sorting, list sweep, graphical sweep, open/short/load correction, and other functions ● No relay switching noise or waiting delay during graphical sweep | ● Built-in calculation functions for conductivity (σ) and dielectric constant (ε) ● Save test data and test conditions (via USB flash drive or internal memory) ● Direct screen capture of graphical sweep images to USB flash drive ● Enhanced test terminal protection function ● Host computer connection interfaces: USB, GPIB, RS-232C, LAN, etc. |
Auto-Balancing Bridge Test Principle
In conventional circuits (left figure), as the frequency increases, the virtual ground gradually deviates from its ideal state, preventing the current signal flowing through the DUT from fully entering the I-V conversion standard resistor Rr, resulting in significant measurement errors. In contrast, the ZX8590 employs an auto-balancing bridge test principle (right figure), upgrading the simple operational amplifier measurement circuit into a vector negative feedback network composed of an Lpot null detection circuit, 0°/90° digital phase detection and modulation/demodulation circuits, and an Lcur high-frequency drive circuit. This ensures that the virtual ground terminal of the measurement circuit is much closer to the ideal state. This architectural innovation enables the ZX8590 to achieve a qualitative leap in measurement accuracy and anti-interference capability.

The following figure shows the measured waveform comparison of the Lcur (virtual ground) between the simple op-amp impedance measurement circuit and the auto-balancing bridge impedance measurement circuit:

Professional and Efficient Material Analysis Platform
◆ Fast and Accurate Dielectric Constant Analysis
The material evaluation measurement system consists of three main components: the precision measurement instrument — ZX8590-30M, the test fixture for securing the Material Under Test (MUT) — ZX85Y77(L), and the software that calculates and displays fundamental material parameters such as dielectric constant (κ) and dissipation factor (D) (the ZX8590-30M has this calculation process built in).

The ZX85Y77(L) is equipped with four interchangeable test electrodes, supporting multiple testing methods for various solid materials using the parallel plate method (contact electrode method / non-contact electrode method / thin-film electrode method). It also features a specifically designed guard electrode to eliminate measurement errors caused by fringing capacitance, significantly enhancing measurement accuracy and ensuring precise determination of dielectric constant.


Simply enter the calculation parameters (length and cross-sectional area), and the instrument will automatically calculate the material's dielectric constant based on the entered parameters and the measured capacitance — no manual calculations required! We highly recommend pairing with the Zhixin Precision dedicated dielectric constant test fixture ZX85Y77(L) for fast and precise measurements!

◆ Permeability Analysis and Derivation

Permeability describes the interaction between a material and a magnetic field, defined as the ratio of magnetic flux density B to the applied magnetic field H. Complex relative permeability (μr*) consists of a real part (μr') representing energy storage and an imaginary part (μr'') representing power dissipation; it can also be expressed as the ratio of complex permeability (μ*) to the permeability of free space (μ0).


The relative permeability of magnetic materials can be derived from the self-inductance of an inductor with a closed magnetic path (e.g., a toroidal core). By winding wire around the core and measuring the inductance across the wire ends, the effective permeability can be conveniently derived. This can be accomplished using the ZX8590-30M Impedance Analyzer by deriving the effective permeability from the inductance measurement results.


◆ Transformer Self-Resonant Frequency (SRF) Measurement

Actual transformers and inductors have distributed inter-turn capacitance (parasitic capacitance), which forms a parallel RLC resonant network with the winding inductance and equivalent series resistance. When the operating frequency reaches the SRF point, the inductive and capacitive reactances cancel each other out, resulting in parallel resonance and peak impedance. Beyond the SRF, the device's electrical characteristics abruptly change from inductive to capacitive.


In the performance evaluation of electronic components, the Self-Resonant Frequency (SRF) of an inductor is a critical parameter. It marks the threshold at which a transformer transitions from an "ideal inductor" to a "capacitive component," directly affecting circuit stability and filtering effectiveness. Using the ZX8590 to accurately measure SRF ensures that power supplies, filters, RF circuits, and other systems remain in the controllable inductive region within the actual operating band, avoiding system failures, EMI violations, or thermal damage caused by characteristic reversal.

◆ Piezoelectric Ceramic Wafer Impedance Analysis

Piezoelectric ceramics exhibit both piezoelectric and ferroelectric properties. Their core characteristic lies in the reversible conversion between mechanical and electrical energy — applying mechanical stress generates charge (direct piezoelectric effect), while applying an electric field produces mechanical deformation (inverse piezoelectric effect).


Through the graphical sweep function of the ZX8590, impedance analysis of piezoelectric ceramic wafers extracts the resonant frequency (fr) and anti-resonant frequency (fa), enabling calculation of the electromechanical coupling coefficient (k). This coefficient directly determines the electrical-to-mechanical energy conversion efficiency of the piezoelectric wafer and is the primary criterion for selecting ultrasonic transducers, piezoelectric actuators, and sensors.


Boosting Automated Production Line Efficiency
◆ Large LCD Screen for Intuitive Display


Parameters & Dimensions
| Test Parameters | C, L, X, B, R, G, D, Q, ESR, Rp, θ, |Z|, |Y|, P, σ, ε | |
| Test Level | 0.005-2 Vrms(<=1 MHz), 0.005-1 Vrms(>1 MHz) | |
| Basic Accuracy | 0.05%; refer to the accuracy table | |
| Test Speed | Fast: 100 meas/sec, Medium: 20 meas/sec, Slow: 6 meas/sec | |
| Display Range | |Z|, R, X | 0.01 mΩ to 99.9999 MΩ |
| |Y|, G, B | 0.00001 μS to 99.9999 S | |
| C | 0.00001 pF to 9.99999 F | |
| D | 0.00001 to 9.99999 | |
| L | 0.00001 μH to 99999.9 H | |
| Q | 0.01 to 99999.9 | |
| θ(RAD) | -3.14159 to 3.14159 | |
| θ(DEG) | -179.999° to 179.999° | |
| Δ% | -999.999% to 999.999% | |
| Internal Bias Option | Optional ±100 mA, ±40 V bias voltage source | |
| Range Mode | Auto, Hold | |
| Trigger Mode | Internal, Manual, Auto, External, Bus | |
| Correction Function | Open/Short, All-frequency zeroing, Spot-frequency zeroing | |
| Equivalent Circuit | Series, Parallel | |
| Comparator | 10-bin sorting, BIN0–BIN9, NG, AUX | |
| PASS, HI, LOW (displayed as PASS/FAIL) | ||
| Interface | RS-232C, USB Host, USB Device, Handler, GPIB (optional) | |
| Temperature & Humidity | 0 °C to 40 °C, Relative Humidity ≤ 75% | |
| Power Requirements | 100 to 120 VAC or 198 to 242 VAC | |
| 46 to 64 Hz, power > 75 VA | ||
| Dimensions (W × H × D) | 400 mm × 132 mm × 410 mm | |
| Weight (net weight) | 8.5 kg | |

Unit: millimeters (mm)
Accessories & Options
ZX85Y47 Kelvin Test Fixture
ZX28Y11AS Four-Terminal Pair (4TP) Test Cable
ZX28Y09 SMD Kelvin Test Cable
ZX28Y08 SMD Test Fixture
ZX85Y77 Dielectric Constant Test Fixture
ZX85Y77L Dielectric Constant Test Fixture
Customer Q&A
Q: When measuring on the single measurement page, the secondary parameter on the second line is clearly outside the upper/lower limits, yet the instrument still displays PASS. Why?
A: If the secondary parameter needs to be included in the judgment, you must enable the "Auxiliary" option in the binning settings.
Q: In the graphical sweep function, the resonant frequency and impedance readings are incorrect. What should I do?
A: The graphical sweep typically requires an all-frequency zeroing. When using test leads, ensure that the lead position during short zeroing is exactly the same as during measurement, to avoid deviations caused by lead movement.
Q: In the graphical sweep function, only one curve is displayed, making it difficult to observe. How can this be resolved?
A: In the graphical sweep settings, change the display mode to "A+B" and set the Y-axis scale to "LOG".
Q: Why does the instrument not alarm on defective products, or why does it keep beeping constantly?
A: ▪ Make sure the upper/lower limits and nominal value are configured, and that the comparator is turned ON.
▪ Check the beep settings under "System". Set "Pass Beep" and "Fail Beep" to the desired mode.
Q: Why do the readings fluctuate significantly and become unstable during zeroing?
A: When shorting the clips, ensure that the corresponding color-matched clips (red-to-blue and black-to-white) are clipped on the same side.
Q: When connecting to a PLC, the instrument output signal is found to be invalid. How can this be resolved?
A: The Handler interface output mode is set to "Hold" by default. You can change it to "Delay Clear" or "Start Clear" mode.
Q: Why do the measured values differ significantly from the standard values?
A: ▪ Check whether the short-circuit reading (pay attention to the clip connection method) is near 0 mΩ. Re-zero the instrument whenever the test environment changes, such as after replacing the fixture or test leads.
▪ Check whether compensation has been applied. Try disabling compensation and re-zeroing.
▪ If the test leads are long, have multiple adapters, or are aged, inspect all four test leads for open circuits or poor contact.
▪ Verify that the instrument's range matches the DUT. A large range mismatch can cause measurement errors.