Product Categories
1500W Series DC Power Supply
Category:
-
File size: 274.9KB
-
File size: 1.6MB
Product Model
Model | Overview | Product Brochure |
| ZX600C-2.6 | Full-Rack; Power: 1500 W / Voltage: 600 V, Current: 2.6 A; Voltage Accuracy: ±0.05% (RS-232C & RS485, TDK-compatible, RJ45 cascade interface). | Click to View |
| ZX300C-5 | Full-Rack; Power: 1500 W / Voltage: 300 V, Current: 5 A; Voltage Accuracy: ±0.05% (RS-232C & RS485, TDK-compatible, RJ45 cascade interface). | Click to View |
| ZX150C-10 | Full-Rack; Power: 1500 W / Voltage: 150 V, Current: 10 A; Voltage Accuracy: ±0.05% (RS-232C & RS485, TDK-compatible, RJ45 cascade interface). | Click to View |
| ZX80C-19 | Full-Rack; Power: 1500 W / Voltage: 80 V, Current: 19 A; Voltage Accuracy: ±0.05% (RS-232C & RS485, TDK-compatible, RJ45 cascade interface). | Click to View |
| ZX60C-25 | Full-Rack; Power: 1500 W / Voltage: 60 V, Current: 25 A; Voltage Accuracy: ±0.05% (RS-232C & RS485, TDK-compatible, RJ45 cascade interface). | Click to View |
| ZX30C-50 | Full-Rack; Power: 1500 W / Voltage: 30 V, Current: 50 A; Voltage Accuracy: ±0.05% (RS-232C & RS485, TDK-compatible, RJ45 cascade interface). | Click to View |
| ZX12.5C-120 | Full-Rack; Power: 1500 W / Voltage: 12.5 V, Current: 120 A; Voltage Accuracy: ±0.05% (RS-232C & RS485, TDK-compatible, RJ45 cascade interface). | Click to View |
| ZX6.0C-200 | Full-Rack; Power: 1500 W / Voltage: 12.5 V, Current: 120 A; Voltage Accuracy: ±0.05% (RS-232C & RS485, TDK-compatible, RJ45 cascade interface). | Click to View |
Functions & Advantages
● 1U ultra-compact slim design ● Supports multi-power supply cascaded RS485 control system (up to 31 units) | ● Active PFC with high power factor ● High resolution and accuracy | ● Coarse and fine adjustment for both voltage and current ● Intelligent temperature-controlled fan with automatic over-temperature protection ● Remote voltage compensation support |
Parameters & Dimensions
| Model | ZX150C-10 | ZX300C-5 | ZX600C-2.6 | |
| Rated Output | Voltage | 0 – 150 V | 0 – 300 V | 0 – 600 V |
| Current | 0 – 10 A | 0 – 5 A | 0 – 2.6 A | |
| Load Regulation | Voltage | < 0.01%±2 mV | < 0.01%±2 mV | < 0.01%±2 mV |
| Current | < 0.02%±5 mA | < 0.02%±5 mA | < 0.02%±5 mA | |
Setting Resolution Readback Resolution | Voltage | 18 mV | 36 mV | 72 mV |
| Current | 1.2 mA | 0.624 mA | 0.312 mA | |
| Setting Accuracy | Voltage | < 0.05%±75 mV | < 0.05%±150 mV | < 0.05%±300 mV |
| Current | < 0.1%±10 mA | < 0.1%±5.2 mA | < 0.1%±2.6 mA | |
| Readback Accuracy | Voltage | 0.1% ± 150 mV | 0.1% ± 300 mV | 0.1% ± 600 mV |
| Current | 0.1% ± 30 mA | 0.1%±15.6 mA | 0.1%±7.8 mA | |
| Ripple & Noise | Voltage | 100 mVp-p | 150 mVp-p | 300 mVp-p |
| Current | 35 mARms | 24 mARms | 12 mARms | |
| Fault Alarm | Supports ALARM LED indicator | |||
| Parallel Connection (Same Specs) | Supported, up to 4 power supplies in parallel | |||
| Series Connection (Same Specs) | Supported, up to 2 power supplies in series | |||
| Output Voltage Programming | 0–5 V / 0–10 V (Analog) or 0–5 kΩ / 0–10 kΩ (Analog) | |||
| Output Current Programming | 0–5 V / 0–10 V (Analog) or 0–5 kΩ / 0–10 kΩ (Analog) | |||
| Output Voltage Monitoring | 0–5 V / 0–10 V (Analog) | |||
| Output Current Monitoring | 0–5 V / 0–10 V (Analog) | |||
| Protection Function | Over Voltage Protection (OVP), Under Voltage Protection (UVL), Over Temperature Protection (OTP), Foldback Protection (FOLD) | |||
| Remote Voltage Compensation | Support | |||
| Multi-Power Supply Cascading Communication | Supported: RS485 communication supports cascading up to 31 power supplies. | |||
| Communication | RS-232C, RS485, standard configuration | |||
| Operating Environment | 0 – 40 °C, 0 – 90% RH, no frost formation | |||
| Power Requirements | AC110 V (99 V to 121 V) / AC220 V (198 V to 242 V), 50 Hz/60 Hz | |||
| Weight | < 8.6 kg | |||
| Dimensions (W × H × D) | 422 mm × 44 mm × 465 mm, excluding the handle; please refer to the installation dimension diagram. | |||
| Model | ZX30C-50 | ZX60C-25 | ZX80C-19 | |
| Rated Output | Voltage | 0 – 30 V | 0 – 60 V | 0 – 80 V |
| Current | 0 – 50 A | 0 – 25 A | 0 – 19 A | |
| Load Regulation | Voltage | < 0.01%±2 mV | < 0.01%±2 mV | < 0.01%±2 mV |
| Current | < 0.02%±5 mA | < 0.02%±5 mA | < 0.02%±5 mA | |
Setting Resolution Readback Resolution | Voltage | 3.6 mV | 7.2 mV | 9.6 mV |
| Current | 6 mA | 3 mA | 2.28 mA | |
| Setting Accuracy | Voltage | < 0.05%±15 mV | < 0.05%±30 mV | < 0.05%±40 mV |
| Current | < 0.1% ± 50 mA | < 0.1%±25 mA | < 0.1%±19 mA | |
| Readback Accuracy | Voltage | 0.1% ± 30 mV | 0.1% ± 60 mV | 0.1% ± 80 mV |
| Current | 0.1% ± 150 mA | 0.1% ± 75 mA | 0.1%±57 mA | |
| Ripple & Noise | Voltage | 60 mVp-p | 60 mVp-p | 80 mVp-p |
| Current | 125 mA Rms | 75 mA Rms | 57 mARms | |
| Fault Alarm | Supports ALARM LED indicator | |||
| Parallel Connection (Same Specs) | Supported, up to 4 power supplies in parallel | |||
| Series Connection (Same Specs) | Supported, up to 2 power supplies in series | |||
| Output Voltage Programming | 0–5 V / 0–10 V (Analog) or 0–5 kΩ / 0–10 kΩ (Analog) | |||
| Output Current Programming | 0–5 V / 0–10 V (Analog) or 0–5 kΩ / 0–10 kΩ (Analog) | |||
| Output Voltage Monitoring | 0–5 V / 0–10 V (Analog) | |||
| Output Current Monitoring | 0–5 V / 0–10 V (Analog) | |||
| Protection Function | Over Voltage Protection (OVP), Under Voltage Protection (UVL), Over Temperature Protection (OTP), Foldback Protection (FOLD) | |||
| Remote Voltage Compensation | Support | |||
| Multi-Power Supply Cascading Communication | Supported: RS485 communication supports cascading up to 31 power supplies. | |||
| Communication | RS-232C, RS485 | |||
| Operating Environment | 0 – 40 °C, 0 – 90% RH, no frost formation | |||
| Power Requirements | AC110 V (99 V to 121 V) / AC220 V (198 V to 242 V), 50 Hz/60 Hz | |||
| Weight | < 8.6 kg | |||
| Dimensions (W × H × D) | 422 mm × 44 mm × 465 mm, excluding the handle; please refer to the installation dimension diagram. | |||
| Model | ZX12.5C-120 | ZX6.0C-200 | |
| Rated Output | Voltage | 0 – 12.5 V | 0 – 6.0 V |
| Current | 0 – 120 A | 0 – 200 A | |
| Load Regulation | Voltage | < 0.01%±2 mV | < 0.01%±2 mV |
| Current | < 0.02%±5 mA | < 0.02%±5 mA | |
Setting Resolution Readback Resolution | Voltage | 1.5 mV | 1 mV |
| Current | 14.4 mA | 30 mA | |
| Setting Accuracy | Voltage | < 0.05%±6.25 mV | < 0.05%±3.0 mV |
| Current | < 0.1%±120 mA | < 0.1%±240 mA | |
| Readback Accuracy | Voltage | 0.1% ± 12.5 mV | 0.1% ± 6.0 mV |
| Current | 0.1%±360 mA | 0.1%±540 mA | |
| Ripple & Noise | Voltage | 60 mVp-p | 60 mVp-p |
| Current | 240 mA Rms | 360 mA Rms | |
| Fault Alarm | Supports ALARM LED indicator | ||
| Parallel Connection (Same Specs) | Supported, up to 4 power supplies in parallel | ||
| Series Connection (Same Specs) | Supported, up to 2 power supplies in series | ||
| Output Voltage Programming | 0–5 V / 0–10 V (Analog) or 0–5 kΩ / 0–10 kΩ (Analog) | ||
| Output Current Programming | 0–5 V / 0–10 V (Analog) or 0–5 kΩ / 0–10 kΩ (Analog) | ||
| Output Voltage Monitoring | 0–5 V / 0–10 V (Analog) | ||
| Output Current Monitoring | 0–5 V / 0–10 V (Analog) | ||
| Protection Function | Over Voltage Protection (OVP), Under Voltage Protection (UVL), Over Temperature Protection (OTP), Foldback Protection (FOLD) | ||
| Remote Voltage Compensation | Support | ||
| Multi-Power Supply Cascading Communication | Supported: RS485 communication supports cascading up to 31 power supplies. | ||
| Communication | RS-232C, RS485 | ||
| Operating Environment | 0 – 40 °C, 0 – 90% RH, no frost formation | ||
| Power Requirements | AC110 V (99 V to 121 V) / AC220 V (198 V to 242 V), 50 Hz/60 Hz | ||
| Weight | < 8.6 kg | ||
| Dimensions (W × H × D) | 422 mm × 44 mm × 465 mm, excluding the handle; please refer to the installation dimension diagram. | ||

Unit: millimeters (mm)