ZX8815/ZX8813/ZX8812 Series Impulse Winding Tester

The ZX8815/ZX8813/ZX8812 series impulse winding testers are specifically designed to meet the testing requirements of wound components. By utilizing a micro-capacitor charged with high voltage (low test energy) to form an RLC parallel resonance with the coil under test, the system analyzes the decaying oscillating waveform. Powered by precise sampling and analysis technology at rates up to 200 Msps, it effectively detects internal insulation defects within the coils (turn-to-turn short circuits, interlayer short circuits, degraded insulation performance, etc.), enabling component manufacturers and end-users to more effectively control and guarantee product quality. The ZX8815/ZX8813/ZX8812 series feature fast measurement speeds and excellent test waveform repeatability. They are widely applicable to enameled wire wound components, including motors, power frequency transformers, relays, switching power supply transformers, and degaussing coils. These series can be integrated into automated test systems to significantly improve testing efficiency.
  • File size: 445.5KB

  • File size: 5.5MB

  • File size: 2.3MB


Product Model

ModelOverviewProduct Brochure
ZX8812-2KVPulse Voltage Output: 50 V–2000 V; Waveform Sampling Rate: 100 Msps.Click to View
ZX8812 A-2KVPulse Voltage Output: 50 V–2000 V; Waveform Sampling Rate: 200 Msps.Click to View
ZX8813Pulse Voltage Output: 30 V–1000 V; Waveform Sampling Rate: 100 Msps; Micro-inductance testing.Click to View
ZX8813APulse Voltage Output: 30 V–1000 V; Waveform Sampling Rate: 200 Msps; Micro-inductance testing.Click to View
ZX8815-3KVPulse Voltage Output: 100 V–5000 V; Waveform Sampling Rate: 100 Msps.Click to View
ZX8815A-3KV Pulse Voltage Output: 100 V–3000 V; Waveform Sampling Rate: 200 Msps.Click to View
ZX8815-5KVPulse Voltage Output: 100 V–5000 V; Waveform Sampling Rate: 100 Msps.Click to View
ZX8815A-5KVPulse Voltage Output: 100 V–5000 V; Waveform Sampling Rate: 200 Msps.Click to View

 

Functions & Advantages

● 65K-color 7-inch TFT 800*480 HD display, selectable Chinese/English interface

● 100 Msps waveform sampling rate, 6500 bytes memory depth (customizable to 200 Msps)

● High-speed testing, up to 15 meas/sec

● Four waveform comparison methods: Area, Differential Area, Corona, and Phase Difference

● Excellent voltage stability and test repeatability for consistent results

● Powerful corona analysis and extraction function to identify potential insulation issues

● Instrument parameters automatically saved with file loading on startup

● Waveform vertical zoom, horizontal zoom, and pan functions for detailed observation

● Sample averaging function, supporting averaging of up to 32 standard waveforms

● Auto standard acquisition mode automatically selects the appropriate sampling rate

● Destructive testing mode to help select the appropriate test voltage

● Degaussing pulse application ensures waveform consistency

● Firmware upgrade via USB HOST

● Foot switch interface for simple and fast measurements

● Multiple interfaces: Handler, RS-232C, USB Device, USB Host, and GPIB (optional)

 

Four Comparison Methods

◆  Area Comparison

Within any specified A–B interval, the waveform area of the tested coil is integrated and compared with the area of the standard waveform over the same interval. The percentage difference between the two waveform areas relative to the standard waveform area in that interval serves as the judgment criterion. Since the waveform area is approximately proportional to energy loss, the area comparison method can be used to evaluate energy loss in coils and effectively detect interlayer and turn-to-turn short circuits.

◆  Differential Area Comparison

Within any specified A–B interval, the Y-axis difference between the tested coil waveform and the standard waveform is calculated (the integration result represents the shaded area within the A–B interval). This difference area is compared with the standard waveform area over the same interval, with the judgment baseline set as a percentage. The Differential Area comparison primarily reflects differences in inductance (L) and energy loss, effectively detecting inductance variations between the standard and tested coils.

◆  Corona Discharge Comparison

Independent of waveform differences, within any specified A–B interval, only the high-frequency components contained in the corona discharge spikes of the tested coil waveform are extracted for area (integration) calculation. The result is then compared with a set value (integer) to determine whether the corona discharge level is acceptable.

◆  Phase Difference Comparison

The user can specify a zero-crossing point (from the 2nd to the 10th) as the comparison position. The instrument evaluates the offset between the tested coil waveform and the standard waveform at this zero-crossing point, compares it with the oscillation period of the standard waveform, and uses the percentage difference as the judgment criterion. As shown in the figure, A–B represents the offset, and C–D represents the oscillation period of the standard waveform — here set to compare the third zero-crossing point.

Parameters & Dimensions

ModelZX8813ZX8812-2KVZX8813AZX8812 A-2KV
Output Pulse Voltage

30 V-1000 V

10 V step

5%±10 V

50 V-2000 V

10 V step

5%±10 V

30 V-1000 V

10 V step

5%±10 V

50 V-2000 V

10 V step

5%±10 V

Inductance Test Range>1 μH>5μH>1 μH>5μH
Max Pulse EnergyMAX 0.02 JMAX 0.08 JMAX 0.02 JMAX 0.08 J

Display

Waveform Display Area

Display Content

800×480 dot matrix graphic LCD

650×250 dot matrix

Magnified display; setting parameters; standard and test waveforms; comparison results; file information, etc.

Waveform SamplingSampling Rate: 100MSa/s to 100kSa/s, 10 ranges
Resolution: 8 bits
Sampling Points: 6500 bytes

Sampling Rate: 200MSa/s to 200kSa/s, 10 ranges
Resolution: 8 bits
Sampling Points: 6500 bytes

Standard Waveform SamplingContinuous Cycle, Single Cycle, Single Sample (Up to 32-sample averaging function)
Input Impedance10 MΩ
Test SpeedUp to 15 meas/sec
Pulse Count

Test pulse: programmable from 1 to 32 cycles

Demagnetization pulses: programmable from 0 to 16 cycles

Display Waveform MeasurementVoltage, Time, Frequency
Trigger ModeInternal / Manual (including foot control) / External / Bus
Comparison Method

AreaSize Comparison, DiffZone Comparison

Corona Comparison, PhaseDiff Comparison

Area Repeatability±1%
Area Difference Repeatability±1%
Judgment OutputPASS/FAIL indication, LED display, Buzzer Alarm
Alarm Volume SelectionLong high beep, Long low beep, Single short beep, Double short beep, OFF
Memory

Internal: 200 sets

External USB flash drive: 500 sets

InterfaceHANDLER, RS-232C, USBCDC, USBTMC, USBHOST

 

ModelZX8815-5KVZX8815-3KVZX8815A-5KVZX8815A-3KV
Output Pulse Voltage

100 V-5000 V

10 V step

5%±10 V

100 V-3000 V

10 V step

5%±10 V

100 V-5000 V

10 V step

5%±10 V

100 V-3000 V

10 V step

5%±10 V

Inductance Test Range>10 μH>10 μH>10 μH>10 μH
Max Pulse EnergyMAX 0.25 JMAX 0.09 JMAX 0.25 JMAX 0.09 J

Display

Waveform Display Area

Display Content

800×480 dot matrix graphic LCD

650×250 dot matrix

Magnified display; setting parameters; standard and test waveforms; comparison results; file information, etc.

Waveform SamplingSampling Rate: 100MSa/s to 100kSa/s, 10 ranges
Resolution: 8 bits
Sampling Points: 6500 bytes

Sampling Rate: 200MSa/s to 200kSa/s, 10 ranges
Resolution: 8 bits
Sampling Points: 6500 bytes

Standard Waveform SamplingContinuous Cycle, Single Cycle, Single Sample (Up to 32-sample averaging function)
Input Impedance10 MΩ
Test SpeedUp to 15 meas/sec
Pulse Count

Test pulse: programmable from 1 to 32 cycles

Demagnetization pulses: programmable from 0 to 16 cycles

Display Waveform MeasurementVoltage, Time, Frequency
Trigger ModeInternal / Manual (including foot control) / External / Bus
Comparison Method

AreaSize Comparison, DiffZone Comparison

Corona Comparison, PhaseDiff Comparison

Area Repeatability±1%
Area Difference Repeatability±1%
Judgment OutputPASS/FAIL indication, LED display, Buzzer Alarm
Alarm Volume SelectionLong high beep, Long low beep, Single short beep, Double short beep, OFF
Memory

Internal: 200 sets

External USB flash drive: 500 sets

InterfaceHANDLER, RS-232C, USBCDC, USBTMC, USBHOST

 

Unit: millimeters (mm)

Accessories & Options

ZX8815Y01R Test Cable

ZX8815Y01R Test Cable

ZX8815Y01B Test Cable

ZX8815Y01B Test Cable

ZX27Y02 Foot Switch

ZX27Y02 Foot Switch

ZX28Y08B Small Inductor Interlayer Test Fixture

ZX28Y08B Small Inductor Interlayer Test Fixture

Software & Resources

Solutions

undefined

undefined

Customer Q&A

Q: How is the test voltage set?

A: There is no specific standard. Generally, 80% of the maximum voltage at which the waveform can still be clearly measured is taken as the test voltage. For example, if waveform distortion begins to appear in a good unit at 3000 V, the test voltage can be set to 2400 V. Adjustments may be made based on the actual defect rate distribution.

 

 

Q: How should the start and end points of a waveform be selected?

A: Typically, the peak of the first oscillation wave is taken as the start point, and the peak of the third or fourth oscillation wave is taken as the end point.

Q: How should the threshold range for area and area difference be configured?

A: There is no specific standard,  it depends on the customer's internal criteria. It is recommended to test several good samples, record the maximum Area and Area Difference values, and slightly relax these values as the judgment thresholds. Then verify the detection capability using defective samples.

Q: What do the area and the area difference respectively represent?

A: ▪ Area: Within any specified A–B interval, the waveform area of the tested coil is integrated and compared with the area of the standard waveform over the same interval. The percentage difference between the two waveform areas relative to the standard waveform area in that interval serves as the judgment criterion, expressed as a percentage.

    ▪ Area Difference: Within any specified A–B interval, the Y-axis deviation between the test waveform and the standard waveform is calculated (the integration result represents the shaded area within the A–B interval). This difference area is compared with the standard waveform area over the same interval, with the judgment baseline set as a percentage.

Total 4 < 1 >